background image

Component Specifications 

 

!

WARNING

 

 

To avoid risk of electrical shock, personal injury, or death, disconnect power to oven and discharge capacitor  

 

before servicing, unless testing requires power. 

16027612  

November 

2006 

  

©2006 Maytag Services 

2

 

Illustration Component 

Testing 

 

Results 

 

 

Thermal Cutout 

Disconnect all wires from TCO. 
Measure resistance across terminals. 
    Cavity Thermal Fuse..................................
    Magnetron TCO .........................................

 
 
Open at 104° C (219° F). 
Open at 138° C (280° F) and  

closed at 82° C (180° F). 

1100 Watt units 

 

1400 and 1800 Watt 
units 

 

Diode Assembly 

Discharge Capacitors

 

 
Remove diode lead from capacitor and 
connect ohmmeter. 
 
Reverse leads for second test. 

Infinite resistance should be 
measured in one direction and 50K

 

or more in the opposite direction. 
 

NOTE:

 Analog meter must contain a 

battery of 6 volts minimum. 

MT2

MT1

GA TE

 

Triac 

Disconnect wires to triac. 
 
Measure resistance from: 
MT1 to MT2 ...................................................
MT1 to Gate...................................................
MT2 to Gate...................................................
All terminals to ground ...................................

Caution - Do not operate oven 
when wire to terminal MT2 is 
removed.

 

Infinite. 
Approximately 40 

 or more. 

Infinite. 
Infinite. 

 

Capacitor 

Discharge Capacitors

 

 
Remove wires from capacitor terminals and 
connect ohmmeter, set on highest 
resistance scale to terminals. 
 
 
 
Also check between each terminal and 
capacitor case. 

 
 

Between Terminals:

 Meter should 

momentarily deflect towards zero 
then return to over 5 M

. If no 

deflection occurs, or if continuous 
deflection occurs, replace capacitor. 
 

Terminal to Case:

 Infinite 

resistance. 

 

Snubber Assembly 

Disconnect wires to snubber. 
 
Measure resistance across terminals.............

 
 
Infinite. 

 

Magnetron 

Discharge Capacitors

 

 
Remove wires from magnetron and connect 
ohmmeter to terminals. Also check 
between each terminal and ground. 

Between Terminals:

 Less than 1 

 
Each terminal to ground measures 
Infinite resistance. 

NOTE:

 This test is not conclusive. If 

oven does not heat and all other 
components test good, replace the 
magnetron and retest. 

 

Blower Motor 

Remove all wires from motor. 
 
Measure resistance across coil......................

 
 
Approximately 30 

Earth

Load

Line

 

Line filter 

Line to Line ....................................................
Load to Load..................................................
Line to Load ...................................................
Any terminal to Earth .....................................

.8 M

.

 

.8 M

.

 

Continuity. 
Infinite. 

Wire Harness 

 

Test continuity of wires .................................. Continuity. 

Содержание Menumaster DEC11E2

Страница 1: ... DEC14E2 UHDC5182 UC18E2 HDC5182 DEC18E2 Power Source Voltage AC 230 VAC 230 VAC 230 VAC 230 VAC 230 VAC 230 VAC Amperage single unit 13 A 13 A 13 A 13 A 13 A 13 A Frequency 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz Single phase 3 wire earthed X X X X X X Plug BS 1363A CEE 7 7 Schuko BS 1363A CEE 7 7 Schuko BS 1363A CEE 7 7 Schuko Power Output Nominal microwave energy IEC705 1100 Watts 1100 Watts 1400 W...

Страница 2: ...MT2 is removed Infinite Approximately 40 Ω or more Infinite Infinite Capacitor Discharge Capacitors Remove wires from capacitor terminals and connect ohmmeter set on highest resistance scale to terminals Also check between each terminal and capacitor case Between Terminals Meter should momentarily deflect towards zero then return to over 5 MΩ If no deflection occurs or if continuous deflection occ...

Страница 3: ...crew on transformer Terminal 4 to any other terminal 1 Ω 1 Ω 1 Ω 45 Ω Infinite resistance If not replace transformer Stirrer motor 230 VAC Remove all wires from motor Measure resistance across terminals Approximately 12 KΩ Primary Logic Secondary Monitor Interlock switch assembly Disconnect wires to switch With door open measure resistance from Terminal C to NO Primary Terminal C to NO Secondary T...

Страница 4: ...tandby 0 9 VAC Cook Line voltage Idle 0 VAC Standby and Cook Line voltage Idle 0 volts Standby and Cook Error Code Table Error Code Corrective Action F1 Replace HV LV Board F2 Replace HV LV Board F3 Replace HV LV Board F5 Replace Touch Panel F4 Replace HV LV Board Usage Test The Usage Test is used to access Magnetron Hours Magnetron Cycles and Door Cycles Use the following procedure to access the ...

Страница 5: ...container to the 1000 ml line with cool tap water NOTE Water temperature should be approximately 60 F 16 C 2 Using the thermometer stir water for five to ten seconds measure and record the temperature T1 3 Place test container of water in the center of oven cavity and close door 4 Heat the water for a 33 second full power cycle NOTE Use a digital watch or a watch with a second hand for ovens with ...

Страница 6: ...NG To avoid risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power 16027612 November 2006 2006 Maytag Services 6 12845002 UHDC5112 DEC11E2 UC11E2 ...

Страница 7: ...d risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power November 2006 16027612 2006 Maytag Services 7 12845002 DANGER HIGH VOLTAGE UHDC5112 DEC11E2 UC11E2 ...

Страница 8: ...electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power 16027612 November 2006 2006 Maytag Services 8 12845102 HDC5142 UHDC5142 DEC14E2 UC14E2 HDC5182 UHDC5182 DEC18E2 UC18E2 ...

Страница 9: ... shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power November 2006 16027612 2006 Maytag Services 9 12845102 DANGER HIGH VOLTAGE HDC5142 UHDC5142 DEC14E2 UC14E2 HDC5182 UHDC5182 DEC18E2 UC18E2 ...

Отзывы: