background image

Component Specifications 

 

!

WARNING

 

 

To avoid risk of electrical shock, personal injury, or death, disconnect power to oven and discharge capacitor  

 

before servicing, unless testing requires power. 

November 2006 

 

16027612 

©2006 Maytag Services

 

5

 

Power Test 

All Amana and Menumaster microwave oven power outputs are rated using the IEC705 standards. Using the IEC705 
test method requires precision measurements and equipment that is not practical to be performed in the field. Using 
the test shown below will indicate if the oven performance is satisfactory. 

 

Test equipment required: 

  1000 ml test container and thermometer (Amana power test kit R0157397 Fahrenheit / Menumaster power 

test kit M95D5 Celsius).  

  Digital watch / watch with a second hand for use on ovens with electromechanical timers. 

Important Notes: 

  Low line voltage will cause low temperature rise / power output. 

  Ovens must be on a dedicated circuit, properly grounded, and polarized. Other equipment on the same 

circuit may cause a low temperature rise / power output. 

  This test and results are not a true IEC705 test procedure and are only intended to provide servicers with an 

easy means of determining if the microwave oven cooking output is correct. 

Procedure 

1.  Fill the test container to the 1000 ml line with cool tap water. 

NOTE:

  Water temperature should be approximately 60°

 

F / 16°

 

C. 

2.  Using the thermometer, stir water for five to ten seconds; measure, and record the temperature (T1). 
3.  Place test container of water in the center of oven cavity and close door. 
4.  Heat the water for a 33-second full power cycle. 

NOTE:

  Use a digital watch or a watch with a second hand for ovens with electromechanical timers. 

1.  At end of the cycle, remove test container. Using the thermometer, stir water for five to ten seconds and record 

temperature (T2). 

2.  Subtract the starting water temperature (T1), from the ending water temperature (T2) to obtain the temperature 

rise (

T). 

3.  If the temperature rise (

T) meets or exceeds the minimum, the test is complete. If the temperature rise (

T) 

fails to meet the minimum temperature rise, test the line voltage to verify it is correct. Then repeat steps 1-6 
making sure to change the water. If the temperature rise (

T) fails to meet the minimum temperature rise again 

the oven will require service. 

Minimum Temperature Rise at Thirty-Three (33) Seconds Run Time 

T Cooking 

T Cooking 

T Cooking 

T Cooking 

(°F) 

Power Output 

(°F) 

Power Output  

(°C) 

Power Output 

(°C) 

Power Output 

10 ................. 1000 20 ................. 2000 5 

.............. 1000 11............ 2000 

11 ................. 1100 21 ................. 2100 5.5 ............ 1100 11.5......... 2100 
12 ................. 1200 22 ................. 2200 6.5 ............ 1200 12............ 2200 
14 ................. 1400 24 ................. 2400 7.5 ............ 1400 13............ 2400 
17 ................. 1700 25 ................. 2500 9.5 ............ 1700 13.5......... 2500 
18 ................. 1800 27 ................. 2700 10 ............. 1800 15............ 2700 
19 ................. 1900 30 ................. 3000 10.5 .......... 1900 16.5......... 3000 

 

Содержание Menumaster DEC11E2

Страница 1: ... DEC14E2 UHDC5182 UC18E2 HDC5182 DEC18E2 Power Source Voltage AC 230 VAC 230 VAC 230 VAC 230 VAC 230 VAC 230 VAC Amperage single unit 13 A 13 A 13 A 13 A 13 A 13 A Frequency 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz Single phase 3 wire earthed X X X X X X Plug BS 1363A CEE 7 7 Schuko BS 1363A CEE 7 7 Schuko BS 1363A CEE 7 7 Schuko Power Output Nominal microwave energy IEC705 1100 Watts 1100 Watts 1400 W...

Страница 2: ...MT2 is removed Infinite Approximately 40 Ω or more Infinite Infinite Capacitor Discharge Capacitors Remove wires from capacitor terminals and connect ohmmeter set on highest resistance scale to terminals Also check between each terminal and capacitor case Between Terminals Meter should momentarily deflect towards zero then return to over 5 MΩ If no deflection occurs or if continuous deflection occ...

Страница 3: ...crew on transformer Terminal 4 to any other terminal 1 Ω 1 Ω 1 Ω 45 Ω Infinite resistance If not replace transformer Stirrer motor 230 VAC Remove all wires from motor Measure resistance across terminals Approximately 12 KΩ Primary Logic Secondary Monitor Interlock switch assembly Disconnect wires to switch With door open measure resistance from Terminal C to NO Primary Terminal C to NO Secondary T...

Страница 4: ...tandby 0 9 VAC Cook Line voltage Idle 0 VAC Standby and Cook Line voltage Idle 0 volts Standby and Cook Error Code Table Error Code Corrective Action F1 Replace HV LV Board F2 Replace HV LV Board F3 Replace HV LV Board F5 Replace Touch Panel F4 Replace HV LV Board Usage Test The Usage Test is used to access Magnetron Hours Magnetron Cycles and Door Cycles Use the following procedure to access the ...

Страница 5: ...container to the 1000 ml line with cool tap water NOTE Water temperature should be approximately 60 F 16 C 2 Using the thermometer stir water for five to ten seconds measure and record the temperature T1 3 Place test container of water in the center of oven cavity and close door 4 Heat the water for a 33 second full power cycle NOTE Use a digital watch or a watch with a second hand for ovens with ...

Страница 6: ...NG To avoid risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power 16027612 November 2006 2006 Maytag Services 6 12845002 UHDC5112 DEC11E2 UC11E2 ...

Страница 7: ...d risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power November 2006 16027612 2006 Maytag Services 7 12845002 DANGER HIGH VOLTAGE UHDC5112 DEC11E2 UC11E2 ...

Страница 8: ...electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power 16027612 November 2006 2006 Maytag Services 8 12845102 HDC5142 UHDC5142 DEC14E2 UC14E2 HDC5182 UHDC5182 DEC18E2 UC18E2 ...

Страница 9: ... shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power November 2006 16027612 2006 Maytag Services 9 12845102 DANGER HIGH VOLTAGE HDC5142 UHDC5142 DEC14E2 UC14E2 HDC5182 UHDC5182 DEC18E2 UC18E2 ...

Отзывы: