42
PCBBF139
STATIC
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
T STAT CALL CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
Ylo
1332
1291
1252
1218
1173
1134
1088
1049
Y
1240
1194
1153
1104
1069
1019
971
929
Ylo
781
628
547
470
396
333
N/A
N/A
Y
1332
1291
1252
1218
1173
1134
1088
1049
Ylo
781
628
547
470
396
333
N/A
N/A
Y
1240
1194
1153
1104
1069
1019
971
929
Ylo
1332
1291
1252
1218
1173
1134
1088
1049
Y
936
888
832
778
723
657
603
549
Ylo
1332
1291
1252
1218
1173
1134
1088
1049
Y
1149
1101
1052
1006
967
916
866
821
Ylo
781
628
547
470
396
333
N/A
N/A
Y
936
888
832
778
723
657
603
549
Ylo
1149
1101
1052
1006
967
916
866
821
Y
1240
1194
1153
1104
1069
1019
971
929
Ylo
1149
1101
1052
1006
967
916
866
821
Y
781
628
547
470
396
333
N/A
N/A
*MEC960603BN - COOLING
DIP Switches
S1-1 S1-2 S1-3
OFF OFF OFF*
ON OFF OFF
ON ON OFF
OFF ON OFF^
OFF OFF ON
OFF ON ON
ON OFF ON^
ON ON ON^
PCBBF139
STATIC
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
T STAT CALL CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
OFF OFF OFF
G
936
888
832
778
723
657
603
549
ON OFF OFF
G
1149
1101
1052
1006
967
916
866
821
ON ON OFF
G
781
628
547
470
396
333
N/A
N/A
OFF ON OFF
G
1332
1291
1252
1218
1173
1134
1088
1049
OFF OFF ON
G
1240
1194
1153
1104
1069
1019
971
929
OFF ON ON
G
936
888
832
778
723
657
603
549
ON OFF ON
G
936
888
832
778
723
657
603
549
ON ON ON
G
936
888
832
778
723
657
603
549
DIP Switches
S2-2 S2-3 S2-4
*MEC960603BN - CONTINOUS FAN
PCBBF139
STATIC
0.6
0.7
0.8
T STAT CALL CFM
RISE
CFM
RISE
CFM
RISE
CFM
RISE
CFM
RISE
CFM
CFM
CFM
W1
936
40
888
42
832
45
778
48
723
52
657
603
549
W2
1149
46
1101
48
1052
51
1006
53
967
55
916
866
821
W1
781
N/A
628
N/A
547
N/A
470
N/A
396
N/A
333
N/A
N/A
W2
1149
N/A
1101
N/A
1052
N/A
1006
N/A
967
N/A
916
866
821
W1
781
N/A
628
N/A
547
N/A
470
N/A
396
N/A
333
N/A
N/A
W2
1332
N/A
1291
N/A
1252
N/A
1218
N/A
1173
N/A
1134
1088
1049
W1
1332
N/A
1292
N/A
1252
N/A
1218
N/A
1173
N/A
1134
1088
1049
W2
1240
N/A
1194
N/A
1153
N/A
1104
N/A
1069
N/A
1019
971
929
*MEC960603BN - HEATING
DIP Switches
S1-4 S2-1
0.1
0.2
0.3
0.4
0.5
OFF OFF*
ON OFF**
ON ON**
OFF ON**
^SINGLE STAGE COOLING
*DEFAULT
**NOT RECOMMENDED
DIP SWITCH SETTINGS