Error Code Table
Error Code
Corrective Action
F1 Replace
HV/LV
Board
F2 Replace
HV/LV
Board
F3 Replace
HV/LV
Board
F4 Replace
HV/LV
Board
F5 Replace
Touch
Panel
Usage Test
The Usage Test is used to access Magnetron Hours, Magnetron Cycles and Door Cycles. Use the following
procedure to access the data:
1. Open
door.
2. Press and hold pad
3
for five (5) seconds.
NOTE:
After five (5) seconds, SErv illuminates in the display.
3. Press
pad
1
for Magnetron Hours.
4. Press
pad
2
for Magnetron Cycles.
5. Press
pad
3
for Door Cycles.
Conditions
Initial Power Up Condition:
Apply power to oven with door closed.
Idle Condition:
Oven plugged in, display blank (no other components operating).
Standby Condition:
Open oven door, light and motors operate.
Cook Condition:
Food load in oven, cook cycle initiated.
F6 Replace
HV/LV
Board
Component Testing Procedures
Содержание HDC-60
Страница 2: ...Table of Contents Important Safety Information 2 5 Quick Start Reference Guide 9 10 3 4 4 6 3 7 3 6 3 ...
Страница 3: ...1 Important Safety Information 1 ...
Страница 13: ...11 HDC 60 Hz Components 4 ...
Страница 18: ...16 Components Sample Door Assembly Door comes in two styles see through door and solid door ...
Страница 19: ...17 Disassembly Inner door window removal Switch replacement door adjustment 5 ...
Страница 26: ...24 Airflow 7 ...
Страница 27: ...25 Air filter must be in place and cleaned regularly Some Models ...
Страница 28: ...26 Component Testing Procedures 8 ...
Страница 34: ...32 Troubleshooting Intial Power Up Standby Condition Cook Condition 9 ...
Страница 38: ...36 Wiring Diagrams Schematics 10 ...
Страница 42: ...40 Schematic Diagram Sample w Invensy Control ending at S N 0911102347 ...
Страница 43: ...41 Notes ...
Страница 44: ...www acpsolutions com 2011 ACP Inc Cedar Rapids Iowa 52404 Part No 16400011 Printed in U S A 08 11 ...