Amana Goodman RSKP0013 Скачать руководство пользователя страница 12

12

Model Starts With

High Speed

VSTM Tap

(Black Wire)

Low Speed

VSTM Tap

(Red Wire)

PTH07*G (00 to 35)

1350

1170

PMH07*G (00 to 35)

1650

1450

PMC07*G (00 to 35)

1350

1170

PMC09*G (00 to 35)

1350

1170

PMC12*G (00 to 35)

1500

1350

PMH074/PTH073H/PTH074H (00 to 35)

1650

1500

PMH094/PTH093H/PTH094H (00 to 35)

1650

1500

PMH124/PTH123H/PTH124H (00 to 35)

1350

1170

PTH153H/PTH154H (00 to 35)

1350

1170

PMC154/PMH153G/PMH154G (00 to 35)

1350

1170

PTC072G/PTC092G (00 to 35)

1650

1500

Indoor Motor Speed Selection

1

2

3

ON/OFF

SWITCH

S

DB

R

TR 1

R

T

R 4

DB

L1

OPTIONAL

AIR

DEHUMIDIFICATION

KIT

6

14

14

>

>

>

>

L2

OPTIONAL ELECTRIC HEATER

OPTIONAL

TRANSFER

FAN

R

6

8

7

2

4

3

1

0

TR 1

To MC

DB

14

S

>

>

>

>

YL

RD

BL

OPTIONAL

LIGHTING

CONTROL

TR 1

To MC

7

A

B

BL

DB

14

S

>

>

>

>

2

5

RD

R

Model Starts With

High Speed

VSTM Tap

(Black Wire)

Low Speed

VSTM Tap

(Red Wire)

DRY093/DRY094

1350

1170

PTC173

1650

1450

HEC073/PTH073/PTH074

1350

1170

PMH094/HEC093/PTH093/PTH094

1350

1170

HEC123/PTH123/PTH124

1500

1350

PTH153/PTH154

1650

1500

PMH153/PMH154

1650

1500

PTC073/PTC074

1350

1170

PTC093/PTC094

1350

1170

PTC123/PTC124

1350

1170

PTC153/PTC154

1650

1500

Outdoor Motor Speed Selection

DIP

SWITCH

1

2

3

4

5

ON

• • • • •

OFF

• • • • •

Daughter Board Device

Address

Switch 1

Switch 2

Switch 3

Switch 4

Switch 5

Smart Vent/Door operations for Power Door/Vent, Economizer and 

Econ) Board 

17

0

0

0

0

1

Transfer Fan

20

0

0

1

0

0

Condensate Pump

21

0

0

1

0

1

Lighting Control

24

0

1

0

0

0

DigiAIR™ Compressor

25

0

1

0

0

1

DigiAIR™ Heater

26

0

1

0

1

0

DigiAIR™ Fan

28

0

1

1

0

0

11

10

14

WIRING DIAGRAMS

Dual Motor (continued)

HI

G

H V

O

LT

A

G

E!

DI

SCO

NNE

CT

 AL

PO

W

ER BE

FO

RE

 S

ERV

ICI

NG

 O

R I

NS

TA

LL

IN

G

 T

HI

S

U

N

IT

.  M

U

LT

IPL

E PO

W

ER

 SO

U

R

C

ES M

AY B

E P

R

ESEN

T.

  F

A

IL

U

R

TO

DO

 S

O

 M

AY

 CAUS

E P

RO

PE

RT

Y DAM

AG

E,

 P

ERS

O

NAL

 INJ

UR

Y O

R DE

AT

H

.

Содержание Goodman RSKP0013

Страница 1: ...operty damage personal injury or death WARNING Cancer and Reproduc ve Harm www P65Warnings ca gov PROP 65 WARNING FOR CALIFORNIA CONSUMERS 0140M00517 A WARNING DESCRIPTION Control board installation procedures are described in detail in these instructions Read and follow these instructions carefully before replacing the control board Failure to do so may result in control board damage Pages 3 thro...

Страница 2: ... IAT BLACK terminal and the RED Thermistor connects to the ICT RED terminal on the control board The YELLOW Thermistor connects to the IDT YELLOW terminal on the control board Note If the unit is a heat pump the BLUE Thermistor connects to the OCT BLUE terminal 10 If a remote thermostat or any low voltage accessory is being used connect the low voltage pin connector to low voltage terminal strip I...

Страница 3: ...o select a configuration feature code press the HEAT key until the desired configuration comes up To scroll to a previously viewed configuration codes press the COOL key Once you have scrolled to the correct feature then to select the option code for your desired configuration press either the up or down key to scroll through the options of the selected feature code To exit configuration mode 1 Pr...

Страница 4: ...l 60 80 60 80 C9 Temp Limiting Heat 68 90 80 68 90 80 8 B 0 O c3 Un rent Cooling Temp 45 95 79 45 95 79 c4 Un rent Heating Temp 45 95 63 45 95 63 0 Not Twinned 5 Twinned F Fahrenheit Scale C Celsius Scale L On Low Fan H On High Fan 0 Off d6 Sensorless Un Occ Time 1 32 18 1 32 18 d7 1st Un Occ Set Back Temp 1 16 2 1 16 2 d8 1st Un Occ Set Back Time 1 5 1 24 1 5 1 24 5 d9 2nd Un Occ Set Back Temp 1 ...

Страница 5: ...or 2 Front Desk 3 Wired Un rented Set Back 4 Emergency Hydronic 5 Load Shedding 6 Alarm Sensor 0 Door Switch 1 Motion Sensor 2 Front Desk 3 Wired Un rented Set Back 4 Emergency Hydronic 5 Load Shedding 6 Alarm Sensor 0 Not used 15 80 25 RH above which kit may run 0 Not used 15 60 25 RH above which kit may run 0 No affect on indoor fan 1 Indoor fan forced to run with Kit uL Config Security Code 00 ...

Страница 6: ... Diagnostic Status Report mode press and hold the up and down arrows and while holding quickly press the COOL key twice Active Failures If there are no active failures or lockouts the display will show a double dash If there is a code listed see the unit Diagnostic Codes chart for a list of definitions Operating Temperatures If not in Diagnostic Status Report Mode enter as instructed above and pre...

Страница 7: ...F3 Indoor Ambient Thermistor reads outside the range 20 F to 200 F Y N Replace black Indoor Ambient Thermistor F4 Indoor Coil Thermistor either above or below operating tolerances N Y Replace Red Indoor Coil Thermistor F5 Wireless Thermostat failure N Y Attempt to rebind Wireless Thermostat or Replace Wireless Thermostat F6 Indoor Discharge Thermistor either above or below operating tolerances N Y...

Страница 8: ... Y W1 CURRENT 1 COOLING UNIT FUNCTION FOR A HEAT PUMP OFF 2 RIBBED WIRE MUST BE CONNECTED AS SHOWN ANTICIPATOR R TO HEAT PUMP W AUXILIARY REMOTE THERMOSTAT OPERATION FAN W ELECTRIC HEAT R TO 2ND STAGE 1ST STAGE G Y W1 HEAT OFF 230 265 C O M TRANS FO RM E R LO AD R BK18 YL10 ELECTRIC GY22 C H HEATER 1 2 F 19 WIRE RD13 S C G N RIBBED CAP OD FAN COMP 5 20 FUSE BK37 BK37 GY21 RD33 7 IF SUPPLY VOLTAGE ...

Страница 9: ...REMOTE THERMOSTAT IAT BLACK MOTOR FAN WH15 M2 FACTORY OR FIELD FACTORY HIGH VOLTAGE LOW VOLTAGE LOW VOLTAGE HIGH VOLTAGE FACTORY OR FIELD FACTORY WIRE LEGEND WIRE LEGEND HIGH VOLTAGE HIGH VOLTAGE FACTORY OR FIELD FACTORY OR FIELD GN 1 GN 1 CHASSIS CHASSIS CONDUCTORS ONLY USE COPPER PANEL PANEL CONTRO L CONTRO L 2 RIBBED WIRE MUST BE CONNECTED AS SHOWN NOTES 1 WARNING DISCONNECT POWER BEFORE SERVIC...

Страница 10: ...TROL SWITCH 2 RIBBED WIRE MUST BE CONNECTED AS SHOWN NOTES 1 WARNING DISCONNECT POWER BEFORE SERVICING WIRING TO UNIT MUST BE PROPERLY POLARIZED FOR 265V AND GROUNDED 3 ON HEAT PUMP MODELS ONLY 4 ON UNITS WITH FRONT DESK CONTROL SWITCH 5 BK18 ON LINE 2 WITH FUSE SHOWN CONNECTED FOR 265V FOR 230V AND 115V CONNECT POWER CORD TO LINE 2 6 IF SUPPLY VOLTAGE IS 208V MOVE 240V LEAD TO 208V TAP ON TRANSFO...

Страница 11: ...FF SWITCH S L2 DB 14 OPTIONAL CONDENSATE PUMP TR 3 TR 1 To MC L2 L1 BU RD OR GY WH 8 S BU DB 120 PK PK COM NO C BK DANGER HIGH VOLTAGE 24VAC TRANSFORMER 12VA CLASS 2 ONLY ON OFF MASTER SWITCH HEATER 1 HEATER 2 LINE 1 IN1 COM IN2 AUXILIARY C R GL W2 Y W1 B GH REMOTE THERMOSTAT IAT BLACK ICT RED OCT BLUE IHD ORANGE OAT GREEN IDT YELLOW REV VALVE FAN HIGH LOW OD FAN HIGH LOW LINE 2 COMPRESSOR L2 L1 M...

Страница 12: ...d VSTM Tap Black Wire Low Speed VSTM Tap Red Wire DRY093 DRY094 1350 1170 PTC173 1650 1450 HEC073 PTH073 PTH074 1350 1170 PMH094 HEC093 PTH093 PTH094 1350 1170 HEC123 PTH123 PTH124 1500 1350 PTH153 PTH154 1650 1500 PMH153 PMH154 1650 1500 PTC073 PTC074 1350 1170 PTC093 PTC094 1350 1170 PTC123 PTC124 1350 1170 PTC153 PTC154 1650 1500 Outdoor Motor Speed Selection DIP SWITCH 1 2 3 4 5 ON OFF Daughte...

Страница 13: ...HEAT FUNCTION CONNECT R TO OFF FAN G COOL G Y W1 HEAT G W2 OR G B Y W1 HEAT PUMP W AUXILIARY ELECTRIC HEAT FUNCTION CONNECT R TO OFF FAN G COOL G Y W1 1ST STAGE HEAT G B Y W1 2ND STAGE HEAT G W2 USE COPPER CONDUCTORS ONLY CHASSIS GN1 CONTROL PANEL WIRE LEGEND HIGH VOLTAGE FACTORY HIGH VOLTAGE FACTORY OR FIELD LOW VOLTAGE FACTORY OR FIELD VT FOR A HEAT PUMP THERMOSTAT USED ON A STRAIGHT COOL UNIT G...

Страница 14: ...ING DISCONNECT POWER BEFORE SERVICING WIRING TO UNIT MUST BE PROPERLY POLARIZED FOR 265V AND GROUNDED WHITE WIRE MUST BE CONNECTED AS SHOWN ON HEAT PUMP MODELS ONLY BK ON LINE 2 WITH FUSE SHOWN CONNECTED FOR 265V FOR 230 V 115 V CONNECTED POWER CORD TO LINE 2 FOR REMOTE OPERATION SEE CONFIGURATION CHART IF SUPPLY VOLTAGE IS 208V 230V USE THE 230V TAP ON TRANSFORMER IF SUPPLY VOLTAGE IS 265V USE TH...

Страница 15: ... USE THE 230V TAP ON TRANSFORMER IF SUPPLY VOLTAGE IS 265V USE THE 265V TAP ON TRANSFORMER 115V TRANSFORMER NOT SHOWN RD COM 1650 1500 1350 1170 7 7 230 265 BK GND TO MOTOR VSTM ID RS485 OUTDOOR MOTOR SPEED SELECTION MODEL STARTS WITH HIGH SPEED VSTM BLACK LOW SPEED VSTM RED PTH073G 00 TO 35 1350 1170 DRY093G 00 TO 35 1350 1170 DRY094G 00 TO 35 1350 1170 PTC173G 00 TO 35 1500 1350 CM OUTDOOR FAN M...

Страница 16: ...MER IF SUPPLY VOLTAGE IS 265V USE THE 265V TAP ON TRANSFORMER 115V TRANSFORMER NOT SHOWN RD COM 1400 1250 1200 1000 7 7 230 265 BK GND TO MOTOR VSTM ID RS485 VSM EM EVAP MOTOR INDOOR MOTOR SPEED SELECTION MODEL STARTS WITH HIGH SPEED VSTM BLACK LOW SPEED VSTM RED M PTH074G 00 TO 35 1250 1000 M PTH093G 00 TO 35 1200 1000 M PTH093G50 1400 1250 M PTH094G 00 TO 35 1200 1000 M PTH094G50 1400 1250 M PTH...

Страница 17: ...17 THIS PAGE INTENTIONALLY LEFT BLANK ...

Страница 18: ...18 THIS PAGE INTENTIONALLY LEFT BLANK ...

Страница 19: ...19 THIS PAGE INTENTIONALLY LEFT BLANK ...

Страница 20: ... 77484 www amana ptac com CUSTOMER FEEDBACK We are very interested in all product comments Please fill out the feedback form on one of the following links Goodman Brand Products http www goodmanmfg com about contact us Amana Brand Products http www amana hac com about us contact us You can also scan the QR code on the right for the product brand you purchased to be directed to the feedback page GO...

Отзывы: