background image

6

Cool/Heat

Switch

Fan 

Switch

Cool/Heat

Temperature

Control Dial

Room Temperature

Thermostat

Thermostat 

Control

Lever

System

Switch

Fan

Switch

Action

OFF

AUTO

None

COOL

AUTO

System only cools, fan
cycles off and on.

COOL

ON

System only cools, fan
runs all the time.

HEAT

AUTO

System only heats, fan
cycles off and on.

HEAT

ON

System only heats, fan
runs all the time.

OFF

ON

No heating or cooling, 
fan runs all the time.

Figure 3

Typical Thermostat

ELECTRICAL COMPONENTS
This furnace is equipped with an electronic ignition device
which lights the burners. It also has a induced draft blower
to exhaust combustion products.

Keep both doors in place except for inspection and mainte-
nance. An interlock switch prevents furnace operation if the
blower door is not in place.

Do not use this furnace if any part has been under water.
Immediately call a qualified servicer to inspect the furnace
and to replace any part of the control system and any gas
control which has been under water.

WARNING

To avoid death, personal injury or property
damage do not remove any internal
compartment covers. Electrical
components are contained in both
compartments. Contact a qualified servicer
at once if an abnormal condition is noticed.

OPERATING INSTRUCTIONS

1. Close the manual gas valve external to the furnace.

2. Turn off the electrical power supply to the furnace.

3. Set room thermostat to lowest possible setting.

4. Remove the louvered door on the front of the furnace

by turning the latch screw 1/4 turn.

5. This furnace is equipped with an ignition device which

automatically lights the burner. Do not try to light burner
by hand.

6. 

White Rodgers Model 36E36 or 36E37 or Honeywell

Model VR-8205: Turn the gas control knob clockwise

 to the OFF position for either the White Rodgers

gas valve (Figure 4) or the Honeywell gas valve (Figure
5).

White Rodgers Model 36E22 or 36E23: Push the
selector switch to "OFF". (Figure 6)

 7. Wait five minutes to clear out any gas. Then smell  for

gas, including near the floor. This is important , be-
cause some types of gas are heavier than air.

8. If you smell gas following the five minute waiting period

in Step 7, immediately follow the instructions on the
cover of this manual. If you do not smell gas after five
minutes:

White Rodgers Model 36E36 or 36E37 or Honeywell
Model VR-8205: Turn the gas control knob counter-
clockwise  

  to the ON position for either the White

Rodgers 36E gas valve (Figure 4) or the Honeywell VR-
8205 gas valve (Figure 5).

White Rodgers Model 36E22 or 36E23: Push the
selector switch to "ON". (Figure 6)

9. Replace the door on the front of the furnace.

10. Open the manual gas valve external to the furnace.

11. Turn on the electrical power supply to the furnace.

12. Set thermostat to desired setting.

Figure 4

White Rodgers

Models 36E36 or 36E37

Figure 5

Honeywell

Model VR-8205

Содержание GDC Series

Страница 1: ...hese instructions is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in t...

Страница 2: ...nstall the product safely and to know it well enough to be able to instruct a customer in its safe use Safety is a matter of common sense a matter of thinking before acting Most dealers have a list of...

Страница 3: ...oduct contains or produces a chemical or chemicals which may cause serious illness or death and which are known to the State of California to cause cancer birth defects or other reproductive harm WARN...

Страница 4: ...sted windows or a moist clammy feeling in the home 3 Smoke from a fireplace won t draw up the chimney 4 Flue gases won t draw up the appliance vent pipe WARNING It is vitally important that the furnac...

Страница 5: ...weather stripping to tighten inside windows usually cor rects this problem The following table shows the recommended maximum indoor humidity in relationship to the outdoor temperatures Temperature F H...

Страница 6: ...off the electrical power supply to the furnace 3 Set room thermostat to lowest possible setting 4 Remove the louvered door on the front of the furnace by turning the latch screw 1 4 turn 5 This furna...

Страница 7: ...l out limit switch is located on one end of the manifold assembly for GUC GUX and GDC furnaces Figure 7 and 8 and in the burner box on GUD and GCD furnaces Figure 10 GDC furnaces installed horizon tal...

Страница 8: ...for filter sizes WARNING To avoid death or personal injury due to electrical shock disconnect the electrical powerbeforeremovingfiltersor performing any maintenance The filter is designed for high ve...

Страница 9: ...ry a permanent filter Both sides of a metal filter should be sprayed with a dust adhesive as recommended on the adhesive container Spray adhesives for use with permanent metal filters can be found at...

Страница 10: ...talled in the duct behind the return grille may be used Clean or replace filters every two months or sooner as required replace with the same size and type filter Dirty filters are the most common cau...

Страница 11: ...ical assistance line for dealers ________________________________________ Outside the U S call 1 319 622 5511 Not a technical assistance line for dealers Your telephone company will bill you for the c...

Страница 12: ...g or illegible contact the installing dealer or Amana Customer Service Department for ordering information W ARNING AVERTISSEMENT THIS COMPARTMENT MUST BE CLOSED EXCEPT WHEN SERVICING CE COMPARTIMENT...

Отзывы: