Amana DRY 093Gxxx series XXX Скачать руководство пользователя страница 8

SS-DRYPTAC www.amana-ptac.com

 PB

www.amana-ptac.com SS-DRYPTAC

P

roduct

 S

PecificationS

P

roduct

 S

PecificationS

Amana® is a trademark of Maytag Corporation or its related companies  and used under license to Goodman Company, L.P.  All rights reserved. Our continuing commitment 

to quality products may mean a change in specifications without notice. © 2013  •  Goodman Company, L.P.  •  Houston, Texas  •  Printed in the USA.

FINISHED FLOOR

42 1/4"

16 1/4"

  MIN

MAIN STUD

JACK STUDS

HEADER - 4" x 4" OR

  DOUBLE 2"x 4" ON EDGE

SUB-FLOOR

CRIPPLE

JACK STUD

ADJUST FRAMING TO

 SECURE THIS DIMENSION

f

raming

 

for

 a

cceSSory

 W

all

 S

leeve

 (WS900d)

Wall Sleeve Opening Height

Should Be Squared with 

Wall Sleeve Opening Width

H = 16¼"

W = 42¼"

Fastening Wall Sleeve
When installed in an opening, the Wall Sleeve must be horizontally level (side-to-side) and pitched ¼ bubble to the outside. (NOTE: To ensure 
unit’s maximum efficiency, DO NOT over- or under-pitch.)
Installation Notes
1.  If Sub-base (PTSB***E) is installed, allow minimum 3¼” height clearance and maximum 5” height clearance between wall sleeve and 

floor; allow minimum 2¾” protrusion from a finished wall. See Note 4 if using hydronic units.

2.  Drain Kit (DK900D) shipped separately. Can be mounted either right side, left side or bottom of sleeve. If mounted to bottom of sleeve, 

allow 2” height clearance from floor to bottom of sleeve.

3.  For UL approval, 265V units must use Amana

®

 brand Sub-base (PTSB***E) or Amana

®

 brand Hard Wire Kit (PTPWHWK4). Overcurrent 

protection on 265V units must be by cartridge-style time delay fuses, which are included and factory-installed on the Amana

®

 brand 

265V chassis.

4.  If Hydronic Kit (HWK03 or HVK03) is installed, Wall Sleeve must extend exactly 3" into the room from the finished interior wall. If using 

the Amana

®

 brand Sub-base (PTSB***E), only the minimum 3¼” height clearance between wall sleeve and floor is permissible. Unit 

must also be operated with a remote-mounted thermostat.

5.  If Duct Kit (MDK02B) is installed, allow a minimum of 2⅜” into the room from the finished interior wall.

Mounting 

Holes

(Drilled by 

Installer)

Plastic

Anchor

Screws

Expansion

Anchor Bolt

Toggle Bolt

Wood Screw

Alternative 

Fastening Method

(Field Supplied)

Wall Sleeve must extend a minimum of ¼” beyond outside wall to allow for proper caulking.

Содержание DRY 093Gxxx series XXX

Страница 1: ...rrosion is a problem Energy Efficiency EER of up to 11 2 to keep energy consumption to a minimum On board Energy Management System Amana brand units are equipped with EMS technology to better control...

Страница 2: ...and when empty signals the PTAC to adjust the temperature to save energy based on programmable setbacks The DigiSmart Wireless Remote Thermostat can mount on the wall anywhere in the guest room Batte...

Страница 3: ...ks EMS Configuration Site Statistics Battery Notices Email Reporting Unit Health Unit Code Alerts Temp Limiting Each PTAC can be configured with a heat ing and cooling temperature set point limit Setb...

Страница 4: ...ion ProtecDon Seacoast Rated Voltage D Power Door 3 230 208V 60 Hz 1 Ph F Fuse Holder 230 208 Only 4 265V 60 Hz 1 Ph H Hydronic Heat Capable P Condensate Pump PTH Only Design Series Q Quiet STC 31 Cha...

Страница 5: ...gerant used in all systems All units meet or exceed ASHRAE 90 1 standards All units less than 250 volts have a Leak Current Detector Interrupter LCDI power cord and meet UL 484 standards Refer to elec...

Страница 6: ...0 BTU h models subtract 70 watts for PT07 09 B A 6 Specify two digit heater kW size to complete model number 7 Total amps for 12 000 BTU h models subtract 0 2 amps for PT07 09 B A 8 R 410A refrigerant...

Страница 7: ...Sleeve and Sub base Accessory 3 1 1 6 1 8 9 9 16 24 5 16 40 42 Location of external drain holes on bottom flange of Wall Sleeve 3 Clearance to side walls Air Flow Air Flow Air Flow Air Discharge Gril...

Страница 8: ...d floor allow minimum 2 protrusion from a finished wall See Note 4 if using hydronic units 2 Drain Kit DK900D shipped separately Can be mounted either right side left side or bottom of sleeve If mount...