Notes
¹  MCA (Minimum Circuit Ampacity) ratings conform to the National Electric Code; however, local codes should apply.
²  Minimum voltage on 230/208-volt models is 197 volts; maximum is 253 volts.
³  Overcurrent protection for all units without electric heaters is 15 amps. See heater performance for total MCA.
⁴  Heating capacity and efficiency based on unit operation without condensate pump; unit automatically switches to electric heat at approximately 24°F 

outdoor ambient.

⁵  Total watts for 12,000 BTU/h models.
⁶  Specify two-digit heater kW size to complete model number.
⁷  Total amps for 12,000 BTU/h models.
⁸  R-410A refrigerant used in all systems.
⁹  All units meet or exceed ASHRAE 90.1 standards.
¹⁰  All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards.
¹¹  Refer to electric heat performance data for total MCA and recommended overcurrent protection. Amps and Watts notation refers to compressor only.

DRY

093G***XXX

DRY

094G***XXX

Voltage 

230 / 208

265

Cooling Performance
Capacity (BTU/h)

8,800/8,600

8,800

Amps

4.6/4.7

4.3

Watts

785/770

785

EER

11.2/11.2

11.2

CFM (Cool/ 
Wet Coil)

High

290

290

Low

264

264

Dehumidification *

2.8

2.8

Heating Performance
Min. Circuit Amps

5.5

5.0

Watts
BTU/h
CFM (Dry Coil)

High

310

310

Low

282

282

Fresh Air, CFM (Fan Only)

65*

65*

Net Weight (lbs.)

98

102

Ship Weight (lbs.)

113

117

*   (Pints/Hr. @ High/Low Speed)
^  Approximately 95 CFM with optional power vent kit. Actual vent CFM performance will 

vary due to application and installation conditions.

Содержание DRY 093Gxxx series XXX

Страница 1: ...rrosion is a problem Energy Efficiency EER of up to 11 2 to keep energy consumption to a minimum On board Energy Management System Amana brand units are equipped with EMS technology to better control...

Страница 2: ...and when empty signals the PTAC to adjust the temperature to save energy based on programmable setbacks The DigiSmart Wireless Remote Thermostat can mount on the wall anywhere in the guest room Batte...

Страница 3: ...ks EMS Configuration Site Statistics Battery Notices Email Reporting Unit Health Unit Code Alerts Temp Limiting Each PTAC can be configured with a heat ing and cooling temperature set point limit Setb...

Страница 4: ...ion ProtecDon Seacoast Rated Voltage D Power Door 3 230 208V 60 Hz 1 Ph F Fuse Holder 230 208 Only 4 265V 60 Hz 1 Ph H Hydronic Heat Capable P Condensate Pump PTH Only Design Series Q Quiet STC 31 Cha...

Страница 5: ...gerant used in all systems All units meet or exceed ASHRAE 90 1 standards All units less than 250 volts have a Leak Current Detector Interrupter LCDI power cord and meet UL 484 standards Refer to elec...

Страница 6: ...0 BTU h models subtract 70 watts for PT07 09 B A 6 Specify two digit heater kW size to complete model number 7 Total amps for 12 000 BTU h models subtract 0 2 amps for PT07 09 B A 8 R 410A refrigerant...

Страница 7: ...Sleeve and Sub base Accessory 3 1 1 6 1 8 9 9 16 24 5 16 40 42 Location of external drain holes on bottom flange of Wall Sleeve 3 Clearance to side walls Air Flow Air Flow Air Flow Air Discharge Gril...

Страница 8: ...d floor allow minimum 2 protrusion from a finished wall See Note 4 if using hydronic units 2 Drain Kit DK900D shipped separately Can be mounted either right side left side or bottom of sleeve If mount...