Amana DigiSmart PTC models Скачать руководство пользователя страница 3

MC-DPTAC

www.amana-ptac.com

3

s

Tandard

 f

eaTures

 (

conT

.)

•  Condensate Dispersion System:

 Our condensate dispersion system removes condensate from indoor cooling operation by throwing 

water directly on to the outdoor coil for rapid evaporation and increased cooling efficiencies. The slinger ring on the new, 
enhanced fan draws water up and into the fan blades. This water is then atomized and evaporated into the atmosphere 
through the condenser. Increased surface area from the coil allows more water to be evaporated on the sides of the coils and 
helps to minimize condensate run-off.

•  Front Desk Control:

 Each unit comes equipped with the DigiSmart™ control and energy management software. With Digi-Smart™ 

using the optional RF Antennae, all units can be wirelessly connected to a central hub for enhanced energy savings and 
diagnostics. Amana brand PTACs also have a low-voltage interface capability with a field-supplied front-desk ON/OFF switch. 
(See Page 4.)

•  Room Freeze Protection:

 When the unit senses temperatures of 40°F or below, the unit activates the fan motor and either the 

electric resistance heater or the hydronic heater.  

•  Easy-to-use Controls:

 No complex controls to confuse your guests and create phone calls for your manager. Controls are easy to 

read, understand, and activate. Our new 7-button control panel provides guests with complete control of the unit for their 
in-room comfort while maintaining overall energy efficiency.

•  Easy to Service with On-Board LED Diagnostics:

 The main components are easily serviced and there is no guessing to determine the 

problem with our easy-to-read diagnostics. 

•  Stonewood Room Front:

 Our Stonewood room front strikes the balance between attractive styling and practical design. Distinc-

tive contours and a modern appearance enhance the character of even the most luxurious room, while the sleek 7

” depth 

maximizes usable space for your guests.

•  Remote Thermostat Control:

 When the DigiSmart™ wireless remote thermostat (DS01E, sold separately) is set up, both the remote 

thermostat and unit control panel continue to control the unit, providing flexibility and home-like system control.  Installa-
tion requires no more than pressing two buttons. No need to run wires or make electrical connections. 

•  Remote Temperature Sensing:

 Guests enjoy ultimate comfort with consistent climate control. When the field-installed thermistor 

(RTS03) is used, the unit-mounted thermostat is overridden to allow more accurate, internal wall-sensing of room ambient 
temperature.

•  Extended Heat Pump Heating:

 Heat pump models will operate in the heating mode down to as low as 24°F outdoor ambient tem-

perature.

•  Zero Floor Clearance:

 The unit can be installed flush to a finished floor, if desired. (Some accessories do not have zero clearance).

•  30-Second Fan-Off Delay:

 The fan continues to run 30 seconds after the compressor has stopped in either cooling or heat pump 

mode and after electric heat has been turned off. This improves efficiency by dispersing the conditioned air on the coils into 
the room.

•  Compressor Lock-In:

 This feature helps prolong the life of the compressor by preventing short-cycling. When the compressor is 

switched from Off to On because room temperature has risen or fallen below the specified limit, it will remain on for at least 
4 minutes. If the temperature set-point is changed during this 4 minutes, the lock-in feature is overridden.

•  Automatic Emergency Heat:

 No more “my unit is not heating” complaints during the middle of the night. Heat pump units will 

automatically switch over to electric resistance heat if the heat pump compressor system fails or if the heating load is greater 
than the unit capacity.

•  Constant Fan Mode:

 Take advantage of each unit’s dual options — select continuous fan operation or cycle the fan ON and OFF 

with the thermostat. Our new 7-button design allows guests to select fan performance while allowing the owner to have the 
unit revert to the desired program of continuous fan or cycle with conditioning.

•  Hidden Ventilation Control:

 The ventilation control lever is hidden from the occupant's view to allow you to manage ventilation 

requirements.

•  High-Pressure Switch:

  Protects the unit from high pressure and damage to the unit, helping to ensure long unit life. 

Содержание DigiSmart PTC models

Страница 1: ...Pumps with our DigiSmart Control Board EMS PTAC Specifications and Accessories Catalog Assembled in the USA for 30 years Units are 100 run tested and triple tested for leakage First Year Warranty Par...

Страница 2: ...one of the most comprehensive warranties in the industry First Year parts labor Second through fifth years parts labor on certain sealed system components second through fifth years on certain functio...

Страница 3: ...mostat and unit control panel continue to control the unit providing flexibility and home like system control Installa tion requires no more than pressing two buttons No need to run wires or make elec...

Страница 4: ...room temperature Best of all no wires to run The PTAC and Thermostat connect at the press of a button and are permanently linked The thermostat and PTAC work in sync to display accurate temperature Th...

Страница 5: ...he network for additional rooms properties System Verification Global Setbacks EMS Configuration Site Statistics Battery Notices Email Reporting Unit Health Unit Code Alerts Temp Limiting Each PTAC ca...

Страница 6: ...as needed in alphabe cal order Design Series Examples G R 410A PTC123E50AXXX PTC073E35CRXX PTC123E50CXXX PTC073E25CQRW Heater Size 00 No Electric Heat 3 5 kW 230 208V 15 1 5 kW 3 7 kW 265V 25 2 5 kW 5...

Страница 7: ...Net Weight lbs 98 102 102 113 Ship Weight lbs 113 117 119 130 Actual vent CFM performance will vary due to application and installation conditions Notes All 265 volt models must use an Amana brand su...

Страница 8: ...mance will vary due to application and installation conditions Notes All 265 volt models must use an Amana brand sub base PTSB4 E or an Amana brand hard wire kit PTPWHWK4 Minimum Circuit Ampacity MCA...

Страница 9: ...ems All units meet or exceed ASHRAE 90 1 standards All units less than 250 volts have a Leak Current Detector Interrupter LCDI power cord and meet UL 484 standards Refer to electric heat performance d...

Страница 10: ...20A PTSB330E 230 208V 30A PTSB420E 265V 15 20A PTSB430E 265V 25A PTSB000E Non electrical Sub base Kit The fully skirted sub base conceals wiring while providing strong support if needed Plug in recept...

Страница 11: ...is rated at 30 amp capacity The switch is for use with and Amana brand standard sub bases or PTPWHWK4 Hard Wire Kit MDK02B Main Duct R 22 MDK01E Main Duct R 410A EDK02B Extension Duct Duct Extension...

Страница 12: ...r and HVK03 steam heat kits KL03B Security Key Lock R 22 KL03E Security Key Lock R 410A Security Key Locks In conjunction with the tamper resistant front the installation of Amana brand security key l...

Страница 13: ...ed into the cabinet front using the cabinet filter guides Before cleaning the intake filters turn the unit off by setting the mode switch to the OFF position Filters should be cleaned as required The...

Страница 14: ...ew 11 3 8 40 21 1 2 1 3 8 13 16 14 1 8 4 2 3 4 15 7 3 8 1 2 O D COPPER DRAIN TUBE AIR DISCHARGE GRILLE IS REVERSIBLE TO PROVIDE EITHER 15 OR 40 DISCHARGE ANGLE HINGED CONTROL DOOR OPTIONAL SUBBASE 13...

Страница 15: ...t side left side or bottom of sleeve If mounted to bottom of sleeve allow 2 height clearance from floor to bottom of sleeve 3 For UL approval 265V units must use Amana brand Sub base PTSB E or Amana b...

Страница 16: ...inted in the USA Packaged Terminal Air Conditioners and Heat Pumps with Control Board 7 Button Control Pad One Touch Activation Total Fan Control Easy to Read Display Assembled in the USA for 30 years...

Отзывы: