12
www.amana-ptac.com
MC-DPTAC
a
ccessories
(
conT
.)
t
heRmoStatS
The following thermostats offer remote control. Any thermostat other than those listed must be submitted to Goodman Company, L.P., for approval prior to use.
PDK3A
230/208V – R-22
PDK4A
265V – R-22
PDK3E
230/208V – R-410A
PDK4E
265V – R-410A
P
oWeR
d
ooR
K
it
Vent door will automatically open when unit fan is on.
HWK03B
Hydronic Water Kit – R-22
HVK03B
Hydronic Steam Kit – R-22
HWK03E
Hydronic Water Kit – R-410A
HVK03E
Hydronic Steam Kit – R-410A
h
ydRoniC
h
eat
K
it
Add-on kits fit all units allowing the addition of hydronic water or hydronic
steam heat to cooling and heating units. The kits feature left- or right-hand
piping. Unit retains complete service access with a kit installed. Unit must be
connected to and operated by a wall thermostat.
Hydronic Heat Kit-Top View
Hydronic Heat Kit-Right View
Hydronic Heat Kit-Side View
VS2WNCA*
2-way/24V/NC/Steam
VS2WNOA*
2-way/24V/NO/Steam
VW2WNCA*
2-way/24V/NC/End Switch
VW2WNOA*
2-way/24V/NO/End Switch
VW3WNC2B*
3-way/24V/NC/NO/End Switch
* Pop-top Actuator
h
ydRoniC
v
alveS
Water and steam valves are available for use with the HWK03 (water) and HVK03
(steam) heat kits.
KL03B
Security Key Lock (R-22)
KL03E
Security Key Lock (R-410A)
S
eCuRity
K
ey
l
oCKS
In conjunction with the tamper-resistant front, the installation of Amana® brand
security key locks prevents tampering of the controls used to set temperature,
heating and cooling functions. UL approved for institutional use only.
RTS03
Remote wall-mounted sensor
R
emote
t
emPeRatuRe
S
enSoR
Unit can be wired to sense room temperature away from the PTAC to have
accurate readings.
DS01E
Thermostat: 2-way communications
DD01E
Occupancy Sensor: EMS activation
DT01A
Antennae / Router
GT01A
Generic Radio Antenna / Router
DD01F
Door Switch: EMS Activation
DP01E
Web-enabled Platform Server
DL01E
Web-enabled Platform Server Link
W
iReleSS
Rf (R
adio
f
RequenCy
) C
ontRolS
All DigiSmart PTACs come factory-ready to be controlled via wireless RF devices.
2.4 Ghz 802 15.4 protocol assures robust communications and response.
Model #
Heat
Stages
Cool
Stages
Fan
Speed
# of Wires
Required
Temp
Limiting
Backlit
Display
Type
Shape &
Orientation
Connection
2246002
1
1
1
5
No
Yes
Digital
Manual
Rect./Horiz.
Wired
2246003
2
2
2
7
Yes
Yes
Digital
Manual
Rect./Horiz.
Wired
2246007
2
2
2
7
Yes
Yes
Digital
Auto-Change
Rect./Horiz.
Wired
2246008
2
2
2
7
Yes
Yes
Digital
Programmable
Rect./Horiz.
Wired
DS01E
2
2
2
0
Yes
Yes
Digital
Manual
Rect./Horiz.
Wireless