Amana DigiSmart PTC models Скачать руководство пользователя страница 13

MC-DPTAC

www.amana-ptac.com

13

a

ccessories

 (

conT

.)

WEMR01W

Recess-mounted door switch

WEMS01B

Surface-mounted door switch (Brown)

WEMS01W

Surface-mounted door switch (White)

W

iRed

 e

neRgy

 m

anagement

 C

ontRol

Includes  PIR  occupancy  sensor  power  from  the  DigiSmart  control  and  door 
switch; cannot be used with a remote wired thermostat.

SECM1001A

Climate Master 12½” Sleeve  
Extension (10 Pack)

SEZA0501A

Zone Aire 11½” Sleeve 
Extension (5 Pack)

W

all

 S

leeve

 e

xtenSion

 a

daPteR

 K

itS

Room-side extension kits to increase the depth of the existing sleeve to allow for 
an industry-standard PTAC to be installed.

PTCB10B

10 Pack for R-22 units

PTCB10E

10 Pack for R-410A units

C

uRtain

 b

affle

 K

it

The color-matched polymer curtain baffles help to prevent curtains from falling 
into  the  discharge  air  stream  and  causing  recirculation,  reducing  efficiencies 
and shortening compressor life.

i

nTake

 a

ir

 f

ilTers

It is extremely important to clean the inlet air filters once a month (or more often if operated in dusty or dirty locations or 
conditions) to properly maintain the operational performance of the PTAC unit. The two intake air filters (constructed of durable 
polypropylene) can be easily inserted into the cabinet front using the cabinet filter guides. Before cleaning the intake filters, turn 
the unit off by setting the mode switch to the OFF position. Filters should be cleaned as required.The following procedure is used 
to remove the intake filters:
1. Facing the unit, pull up on the filter handles located at the front top of the unit.
2. Pull each filter upward and remove.
3. Clean filters with vacuum or with running water. Reverse this procedure to reinstall the filters.

Note:

  Accessory filter kits are available from your sales person. All filters are permanent and cleanable. Consult your  

       I&O Manual for other monthly cleaning instructions.

m

onTHly

 m

ainTenance

s

Pare

 f

ilTers

 

Helps keep dirt and lint out of the air and off the coil, 
thus  increasing  the  unit's  efficiency.  Amana®  brand 
filters are easy to remove, wash and replace.

FK10A

10-pack - A Series

FK10B

10-pack - B, C & D Series

FK10E

10-pack - E Series (This 
model requires 2 filters 
per change.)

r

ePlacemenT

 c

Harcoal

 f

ilTer

 k

iT

Absorbs airborne odors caused by cigarette, pipe 
or cigar smoke and odors caused by mold, mildew, 
etc.  Filters  are  made  of  polyester  fibers  coated  with 
activated charcoal and are individually wrapped. These 
filters  are  permanent  and  can  be  washed  or  cleaned. 
Call your Amana® brand PTAC sales person for details. 
10 filters per pack.

CFK10A

10-pack - A Series (R-22)

CFK10B

10-pack - B, C & D Series (R-22)

Содержание DigiSmart PTC models

Страница 1: ...Pumps with our DigiSmart Control Board EMS PTAC Specifications and Accessories Catalog Assembled in the USA for 30 years Units are 100 run tested and triple tested for leakage First Year Warranty Par...

Страница 2: ...one of the most comprehensive warranties in the industry First Year parts labor Second through fifth years parts labor on certain sealed system components second through fifth years on certain functio...

Страница 3: ...mostat and unit control panel continue to control the unit providing flexibility and home like system control Installa tion requires no more than pressing two buttons No need to run wires or make elec...

Страница 4: ...room temperature Best of all no wires to run The PTAC and Thermostat connect at the press of a button and are permanently linked The thermostat and PTAC work in sync to display accurate temperature Th...

Страница 5: ...he network for additional rooms properties System Verification Global Setbacks EMS Configuration Site Statistics Battery Notices Email Reporting Unit Health Unit Code Alerts Temp Limiting Each PTAC ca...

Страница 6: ...as needed in alphabe cal order Design Series Examples G R 410A PTC123E50AXXX PTC073E35CRXX PTC123E50CXXX PTC073E25CQRW Heater Size 00 No Electric Heat 3 5 kW 230 208V 15 1 5 kW 3 7 kW 265V 25 2 5 kW 5...

Страница 7: ...Net Weight lbs 98 102 102 113 Ship Weight lbs 113 117 119 130 Actual vent CFM performance will vary due to application and installation conditions Notes All 265 volt models must use an Amana brand su...

Страница 8: ...mance will vary due to application and installation conditions Notes All 265 volt models must use an Amana brand sub base PTSB4 E or an Amana brand hard wire kit PTPWHWK4 Minimum Circuit Ampacity MCA...

Страница 9: ...ems All units meet or exceed ASHRAE 90 1 standards All units less than 250 volts have a Leak Current Detector Interrupter LCDI power cord and meet UL 484 standards Refer to electric heat performance d...

Страница 10: ...20A PTSB330E 230 208V 30A PTSB420E 265V 15 20A PTSB430E 265V 25A PTSB000E Non electrical Sub base Kit The fully skirted sub base conceals wiring while providing strong support if needed Plug in recept...

Страница 11: ...is rated at 30 amp capacity The switch is for use with and Amana brand standard sub bases or PTPWHWK4 Hard Wire Kit MDK02B Main Duct R 22 MDK01E Main Duct R 410A EDK02B Extension Duct Duct Extension...

Страница 12: ...r and HVK03 steam heat kits KL03B Security Key Lock R 22 KL03E Security Key Lock R 410A Security Key Locks In conjunction with the tamper resistant front the installation of Amana brand security key l...

Страница 13: ...ed into the cabinet front using the cabinet filter guides Before cleaning the intake filters turn the unit off by setting the mode switch to the OFF position Filters should be cleaned as required The...