Amana DD01E Скачать руководство пользователя страница 7

7

ABOVE SHOWS MAGNET 15/16” FROM THE SENSOR MOUNTING PLATE IN DIFFERENT SLOT POSITIONS

Place magnet in Position A
in instances when the door

and frame align.

CONSTRUCTION STYLE 1

POSITION A

CONSTRUCTION STYLE 2

Place magnet in Position B
in instances when the door

extends into the room

beyond the door frame.

POSITION B

CONSTRUCTION STYLE 3

Place magnet in Position C

in instances when the door

extends into the room

beyond the door frame.

POSITION A

Spacers

(Two (2) 1/4” spacers
are included in kit)

CONSTRUCTION STYLE 4

Place magnet in Position A
in instances when the door

frame extends into the room

beyond the door.

NOTE: Two (2) 1/4” spacers are provided in this kit for instances where the door is recessed behind the door trim.

See Construction style 4 above.

There is a line on the bottom of the DD01E and DD01F to assist in aligning the magnet in the proper bucket location.

Above graphics are for example only. Always measure and place the magnet in the proper slot

to obtain the 15/16” needed between the magnet and the sensor mounting plate on the door frame.

Содержание DD01E

Страница 1: ...installation or repair it is possible to place yourself in a position which is more hazardous than when the unit is in operation Remember it is your responsibility to install the product safely and t...

Страница 2: ...r at the fuse box or circuit breaker 2 If the cabinet front is screwed to the chassis remove the 1 4 screw or screws See following figure Front Mounting Screw accessed through louvers 3 Remove cabinet...

Страница 3: ...plate 4 If mounting in drywall tap plastic anchors into wall For other surfaces drill a 3 16 hole 5 Screw mounting plate to the wall DO NOT SNAP THER MOSTAT INTO PLACE UNTIL AFTER BINDING PROCESS See...

Страница 4: ...door frame the sensor will need to be mounted on the wall next to the door In these cases a wired magnet a field supplied single pole single throw wired magnet can be recessed or surface mounted andw...

Страница 5: ...r where it will be as close as possible to the bottom of the motion sensor but no more then 1 8 from the bottom center of the sensor DD01E or DD01F when the door is closed Select the correct slot in t...

Страница 6: ...Screw location located on each side of sensor SIDE VIEW P O S I T I O N A P O S I T I O N B P O S I T I O N C MAGNET SLOTS MAGNET HOLDER TOP VIEW INSTALL THE MAGNET IN THE CORRECT SLOT 15 16th FROM B...

Страница 7: ...oor frame POSITION A Spacers Two 2 1 4 spacers are included in kit CONSTRUCTION STYLE 4 Place magnet in Position A in instances when the door frame extends into the room beyond the door NOTE Two 2 1 4...

Страница 8: ...cally self configure to activate pre configured energy management routine when the DD01E or DD01F is installed and bound to the PTAC Additionally the setback times and setback temperatures can be chan...

Страница 9: ...s the HEAT key until appears then press the up and down arrows to select 01 3 If a room contains more than one unit a suite a suffix must also be entered to identify which unit is in the main room and...

Страница 10: ...lease the white button a second time Skip this step if there is no thermostat 3 Press and then immediately release the white tactile button on the back of the DD01 motion sensor or should now be displ...

Страница 11: ...00 99 00 99 C5 Room I D Digit 3 4 00 99 00 99 C6 Wired or Wireless Occupancy 0 Off 1 On 18 18 Hour Automatic Entry C8 Temp Limiting Cool 60 72 60 72 C9 Temp Limiting Heat 68 90 80 68 90 80 Cd English...

Страница 12: ...back temperature press the HEAT key until feature code comes up To scroll to a previously viewed feature codes press the COOL key Once you have scrolled to the feature press either the up or down arr...

Страница 13: ...10 To exit configuration mode Press the OFF key NOTE Configuration feature mode will also automatically exit if no keys are pressed for a period of two 2 minutes The changes made in configuration mode...

Страница 14: ...between the equipment and all persons This equipment is authorized for use under the United States Federal Communication Commission Rules and Regulations Code of Federal Regulations Chapter 47 part 1...

Страница 15: ...15 THIS PAGE LEFT BLANK INTENTIONALLY...

Страница 16: ...k of Maytag Corporation or its related companies and is used under license to Goodman Company L P Houston TX All rights reserved PTAC Direct Sales Inc 185 S Kimball Ave Suite 130 Southlake TX 76092 87...

Отзывы: