Amana DD01E Скачать руководство пользователя страница 5

5

+

-

+

-

Binding Button

Wired

Magnet
Connection

Power Connection

Battery Holder

Viewed from the back with the power block

 in upper right corner.

Pins

+

-

Binding Button

Wired
Magnet
Connection

Power Connection

Battery

Holder

Jumper
on Pins

Battery
Connection

Note: For battery connection, the jumper must be placed
as shown above

+

-

Binding Button

Wired
Magnet
Connection

Power Connection

Battery
Holder

Jumper
on Pins
Powered
Connection

Note: For 24v powered connection, the jumper must be
placed as shown above

Door Magnet Installation

NOTE: Magnet buckets are shipped from the factory with the
magnets in position A.  The position may change based on
the door and door frame alignment on page 6.

Mount the door magnet holder on the front of the door
where it will be as close as possible to the bottom of the
motion sensor but no more then 1/8" from the bottom center
of the sensor (DD01E or DD01F) when the door is closed.
Select the correct slot in the magnet holder (there are three
slots) to obtain 15/16" from back of sensor mounting plate
to the center of the magnet. (If you can easily slide a
business card between the magnet and the DD01E or DD01F
sensor, unit is properly placed vertically.) See image below
for magnet and sensor alignment.
Screw in place with the 2 screws provided. Open and close
the door to make sure that the magnet holder and motion
sensor will not interfere with normal opening and closing
of the door. See images on pages five and six.

CENTER OF MAGNET

(IN HOLDER)

MUST BE 15/16” FROM THE

SENSOR MOUNTING PLATE

SENSOR

MOUNTING

PLATE

ALIGNMENT

GUIDES

ON BOTTOM

OF DD01E

Do NOT install batteries until you are ready to test the
magnet location with DD01E.

Содержание DD01E

Страница 1: ...installation or repair it is possible to place yourself in a position which is more hazardous than when the unit is in operation Remember it is your responsibility to install the product safely and t...

Страница 2: ...r at the fuse box or circuit breaker 2 If the cabinet front is screwed to the chassis remove the 1 4 screw or screws See following figure Front Mounting Screw accessed through louvers 3 Remove cabinet...

Страница 3: ...plate 4 If mounting in drywall tap plastic anchors into wall For other surfaces drill a 3 16 hole 5 Screw mounting plate to the wall DO NOT SNAP THER MOSTAT INTO PLACE UNTIL AFTER BINDING PROCESS See...

Страница 4: ...door frame the sensor will need to be mounted on the wall next to the door In these cases a wired magnet a field supplied single pole single throw wired magnet can be recessed or surface mounted andw...

Страница 5: ...r where it will be as close as possible to the bottom of the motion sensor but no more then 1 8 from the bottom center of the sensor DD01E or DD01F when the door is closed Select the correct slot in t...

Страница 6: ...Screw location located on each side of sensor SIDE VIEW P O S I T I O N A P O S I T I O N B P O S I T I O N C MAGNET SLOTS MAGNET HOLDER TOP VIEW INSTALL THE MAGNET IN THE CORRECT SLOT 15 16th FROM B...

Страница 7: ...oor frame POSITION A Spacers Two 2 1 4 spacers are included in kit CONSTRUCTION STYLE 4 Place magnet in Position A in instances when the door frame extends into the room beyond the door NOTE Two 2 1 4...

Страница 8: ...cally self configure to activate pre configured energy management routine when the DD01E or DD01F is installed and bound to the PTAC Additionally the setback times and setback temperatures can be chan...

Страница 9: ...s the HEAT key until appears then press the up and down arrows to select 01 3 If a room contains more than one unit a suite a suffix must also be entered to identify which unit is in the main room and...

Страница 10: ...lease the white button a second time Skip this step if there is no thermostat 3 Press and then immediately release the white tactile button on the back of the DD01 motion sensor or should now be displ...

Страница 11: ...00 99 00 99 C5 Room I D Digit 3 4 00 99 00 99 C6 Wired or Wireless Occupancy 0 Off 1 On 18 18 Hour Automatic Entry C8 Temp Limiting Cool 60 72 60 72 C9 Temp Limiting Heat 68 90 80 68 90 80 Cd English...

Страница 12: ...back temperature press the HEAT key until feature code comes up To scroll to a previously viewed feature codes press the COOL key Once you have scrolled to the feature press either the up or down arr...

Страница 13: ...10 To exit configuration mode Press the OFF key NOTE Configuration feature mode will also automatically exit if no keys are pressed for a period of two 2 minutes The changes made in configuration mode...

Страница 14: ...between the equipment and all persons This equipment is authorized for use under the United States Federal Communication Commission Rules and Regulations Code of Federal Regulations Chapter 47 part 1...

Страница 15: ...15 THIS PAGE LEFT BLANK INTENTIONALLY...

Страница 16: ...k of Maytag Corporation or its related companies and is used under license to Goodman Company L P Houston TX All rights reserved PTAC Direct Sales Inc 185 S Kimball Ave Suite 130 Southlake TX 76092 87...

Отзывы: