26
T
O
PREVENT
PERSONAL
INJURY
OR
DEATH
DUE
TO
ELECTRIC
SHOCK
,
DISCONNECT
ELECTRICAL
POWER
BEFORE
INSTALLING
OR
SERVICING
THIS
UNIT
.
WARNING
HIGH VOLTAGE !
T
O
AVOID
THE
RISK
OF
INJURY
,
ELECTRICAL
SHOCK
OR
DEATH
,
THE
FURNACE
MUST
BE
ELECTRICALLY
GROUNDED
IN
ACCORDANCE
WITH
LOCAL
CODES
OR
IN
THEIR
ABSENCE
,
WITH
THE
LATEST
EDITION
OF
THE
N
ATIONAL
E
LECTRIC
C
ODE
.
WARNING
WARNING
T
O
AVOID
THE
RISK
OF
INJURY
,
ELECTRICAL
SHOCK
OR
DEATH
,
THE
FURNACE
MUST
BE
ELECTRICALLY
GROUNDED
IN
ACCORDANCE
WITH
LOCAL
CODES
OR
,
IN
THEIR
ABSENCE
,
WITH
THE
LATEST
EDITION
OF
THE
N
ATIONAL
E
LECTRICAL
C
ODE
.
115 Volt Line Voltage Connection of Accessories
(Humidifier and Electronic Air Cleaner)
The furnace integrated control module is equipped with
line voltage accessory terminals for controlling power to
an optional field-supplied humidifier and/or electronic air
cleaner.
Turn OFF power to the furnace before installing any
accessories. Follow the humidifier or air cleaner
manufacturers’ instructions for locating, mounting,
grounding, and controlling these accessories. Accessory
wiring connections are to be made through the 1/4” quick
connect terminals provided on the furnace integrated
control module. The humidifier hot terminal is identified
as 120V HUM-H, its neutral terminal is identified as 120V
HUM-N. The electronic air cleaner hot terminal is identified
as EAC-H, its neutral terminal is identified as 120V
EAC-N. All field wiring must conform to applicable codes.
Connections should be made as shown. (See Figure 32)
If it is necessary for the installer to supply additional line
voltage wiring to the inside of the furnace, the wiring
must conform to all local codes, and have a minimum
temperature rating of 105°C. All line voltage wire splices
must be made inside the furnace junction box.
The integrated control module humidifier terminal 120V
HUM-H is energized with 115 volts whenever the induced
draft blower is energized. This terminal can also be used
to provide 115 volt power to a humidifier transformer. The
remaining primary transformer wire would be connected
to the Line N on the control board. The integrated control
module electronic air cleaner terminals EAC-H is energized
with 115 volts whenever the circulator blower is energized.
NOTE: Wire routing must not to interfere with
circulator blower operation, filter removal, or routine
maintenance.
115 VAC EAC
115 VAC HUM
W R G C Y
Figure 32
Connection of 24 Volt Humidifier
The integrated control module single humidifier terminal
“24 V HUM” is energized with 24 volts whenever the
induced draft blower is energized. Connect the common
side of the 24 volt humidifier to the “C” terminal of the
thermostat terminal strip on the control board.
24 VOLT HUM. &
HUMIDISTAT
W R G C Y
24V HUM Terminal is
energized when pressure
switch is closed
Figure 33