Carefully read all instructions for the installation prior to installing
unit. Make sure each step or procedure is understood and any
special considerations are taken into account before starting
installation.  Assemble all tools, hardware and supplies needed to
complete the installation. Some items may need to be purchased
locally. After deciding where to install unit, closely look the location
over - both the inside and outside of home. Note any potential
obstacles or problems that might be encountered as noted in this
manual. Choose a more suitable location if necessary.

IMPORTANT NOTE:

   If a crankcase heater is used, the unit

should be energized 24 hours prior to compressor start up to
ensure crankcase heater has sufficiently warmed the compres-
sor.  Compressor damage may occur if this step is not fol-
lowed.

SHIPPING INSPECTION

Upon receiving the unit, inspect it for damage from shipment.
Claims for damage, either shipping or concealed, should be filed
immediately with the shipping company. Check the unit model
number, specifications, electrical characteristics and accessories
to determine if they are correct. In the event an incorrect unit is
shipped, it must be returned to the supplier and must NOT be
installed. The manufacturer assumes no responsibility for
installation of incorrectly shipped units.

REPLACEMENT PARTS

O

RDERING

 P

ARTS

When reporting shortages or damages, or ordering repair parts,
give the complete unit model and serial numbers as stamped
on the unit’s nameplate.
Replacement parts for this appliance are available through your
contractor or local distributor. For the location of your nearest
distributor, consult the white business pages, the yellow page
section of the local telephone book or contact:

CONSUMER AFFAIRS

GOODMAN MANUFACTURING COMPANY, L.P.

7401 SECURITY WAY

HOUSTON, TEXAS 77040

877-254-4729

SAFETY INSTRUCTIONS

The following symbols and labels are used throughout this manual
to indicate immediate or potential safety hazards.  It is the owner’s
and installer’s responsibility to read and comply with all safety
information and instructions accompanying these symbols.  Failure
to heed safety information increases the risk of personal injury,
property damage, and/or product damage.

Содержание APG1624060M41

Страница 1: ...15 Goodman Manufacturing Company L P INSTALLATION INSTRUCTIONS FOR SELF CONTAINED PACKAGE HEAT PUMP UNITS APH16 M SERIES NOTE Please contact your distributor or our website for the applicable Specific...

Страница 2: ...8 CONDENSATE DRAIN 8 WIRING 8 HIGH VOLTAGE WIRING 8 LOW VOLTAGE WIRING 9 INTERNAL WIRING 9 STARTUP ADJUSTMENTS AND CHECKS 9 COOLING START UP PROCEDURES 9 HEAT PUMP START UP PROCEDURE 9 FINAL SYSTEM CH...

Страница 3: ...NG REVERSING VALVE THIS MAY BE DUE TO 15 APPENDIX 16 TROUBLESHOOTING CHART 17 APH16 BLOWER PERFORMANCE DATA 18 APH16 CFM OUTPUT AND DIP SWITCH SETTINGS 19 CFM OUTPUT FOR DIP SWITCH COMBINATIONS 1 2 EL...

Страница 4: ...ck the unit model number specifications electrical characteristics and accessories to determine if they are correct In the event an incorrect unit is shipped it must be returned to the supplier and mu...

Страница 5: ...necessary internal electrical wiring The heat pump also includes a reversing valve solenoid defrost thermostat and control and loss of charge protection The system is factory evacuated charged and per...

Страница 6: ...cient structural strength to carry the weight of the unit s and snow or water loads as required by local codes Consult a structural engineer to determine the weight capabilities of the roof The unit m...

Страница 7: ...methods of Air Conditioning Contractors of America Manual D Residential or Manual Q Commercial All duct work exposed to the outdoors must include a weatherproof barrier and adequate insulation A duct...

Страница 8: ...isconnect near the unit Determine wire sizes and overcurrent protection from the unit nameplate ampacity and in accordance with the Minimum Filter Size or the N E C The wiring should never be sized sm...

Страница 9: ...on 3 Turn on the electrical supply at the disconnect 4 Turn the fan switch to the ON position The blower should begin ramping up immediately 5 Turn the fan switch to AUTO position The blower should be...

Страница 10: ...tc Set the thermostat at the appropriate setting for cooling and heating or automatic changeover for normal use NOTE The Cooling Start up Procedure is a recommended step as it serves as an system indi...

Страница 11: ...ity of the heat pump This phenomenon is a characteristic of a heat pump It is a good practice to provide supplementary heat for all heat pump installations in areas where the temperature drops below 4...

Страница 12: ...pressure As long as ESP is maintained the unit will deliver the proper air up to the maximum static pressure listed for the CFM required by the application i e home building etc In general 400 CFM per...

Страница 13: ...ll thermometer on liquid small line near liquid line access fitting with adequate contact and insulate for best possible reading 3 Check subcooling and superheat Two stage systems running on high stag...

Страница 14: ...before taking readings Do not adjust TXV more than 1 4 of a turn between readings ELECTRICAL ADJUSTMENTS This series of electric cooling and heat pump package equipment is designed to accept a field i...

Страница 15: ...ACT The unit s defrost terminating sensor must make good thermal contact with the outdoor coil tubing Poor contact may not terminate the unit s defrost cycle quickly enough to prevent the unit from cu...

Страница 16: ...16 APPENDIX...

Страница 17: ...grounded or open winding open internal overload b Wait at least 2 hours for overload to reset If still open replace the compressor c Low voltage connection c At compressor terminals voltage must be w...

Страница 18: ...al 1 225 D Plus 880 D Plus 880 D Plus 1 348 D Plus 1 348 C Minus 900 C Minus 900 C Minus 1 260 C Minus 1 260 C Normal 1 000 C Normal 1 000 C Normal 1 400 C Normal 1 400 C Plus 1 100 C Plus 1 100 C Plu...

Страница 19: ...D On On 700 A Off Off 1250 F B On Off 1100 C Off On 1000 D On On 800 A Off Off 1250 F B On Off 1100 C Off On 1000 D On On 800 A Off Off 1800 B On Off 1700 C Off On 1400 F D On On 1225 A Off Off 1800 F...

Страница 20: ...S 3 MIN 12 MIN 36 MIN FOR SERVICE 48 MIN 12 MIN 36 MIN FOR SERVICE NOTE Roof overhang should be no more than 36 BLOWER ACCESS PANEL 2 34 51 47 SUPPLY 1 3 8 A RETURN POWER WIRE ENTRANCE 4 1 8 2 1 8 6 1...

Страница 21: ...r rubbing and leaks Repair if necessary Check unit wiring to ensure it is not in contact with refrigerant piping or sharp metal edges Check all electrical connections and terminals Tighten as needed V...

Страница 22: ...Amps Blower Amps Condenser Fan Amps ELECTRICAL Total External Static Pressure Blower Wheel RPM TEMPERATURES Outdoor Air Temperature Return Air Temperature Cooling Supply Air Temperature Discharge Cir...

Страница 23: ...23 THIS PAGE LEFT INTENTIONALLYBLANK...

Страница 24: ...24 Goodman Manufacturing Company L P 5151 San Felipe Suite 500 Houston TX 77056 www goodmanmfg com www amana hac com 2015 Goodman Manufacturing Company L P...

Отзывы: