SS-AMVS80-U
www.amana-hac.com
7
Wiring Diagram
Wiring is subject t
o chang
e. Alw
ay
s
re
fer
to
the wiring
diag
ram on
the
unit
for the mos
t up-t
o-da
te
wiring.
⚠
W
arning
High
Volt
ag
e:
Disc
onn
ect
all
po
w
er
be
for
e
ser
vicing
or
in
st
alling
this
unit.
Multiple
po
w
er
sour
ces
ma
y be pr
esen
t. F
ailur
e
to do
so ma
y c
ause pr
operty
damag
e,
per
sonal
injur
y,
or dea
th.
⚡
0140F02477-A
FUSE 3 A
MICRO
TO
TR (11)
G
TH (4)
24
V T
H
ER
M
O
ST
AT
C
O
NN
EC
TIO
N
S
VALVE
GAS
TRANSFORMER
(6)
Y
HLO (10)
GND (5)
W
R
CONTROLS
AUTO RESET AUXILIARY LIMIT
BOX LIMIT
AUTO RESET BURNER
C
PSO (7)
PRESS.
GND
PS1 (2)
LIMIT CONTROL
AUTO RESET PRIMARY
24 VAC
INTEGRATED CONTROL MODULE
BLWR
AIR
INDOOR
CIRCULATOR
TX (3)
RX (2)
+ VDC (1)
GND (4)
R
TO
MICRO
TO
TO +VDC
EAC
HUM-IN
ID
NEUTRAL
WIRING TO UNIT
L
INT
EG
RA
TE
D CO
NT
RO
L M
O
DUL
E
HOT SURFACE
INDUCTOR COIL
GND
BLWR
NEUTRAL
WARNING:
GROUNDED.
OVERCURRENT PROTECTION DEVICE
MUST BE PROPERLY
SWITCH
NEUTRAL
ELECTRONIC
AIR
(ON SOME MODELS)
IGN
DISCONNECT
FS
POLARIZED AND
NEUTRAL
LINE
NEUTRAL
JUNCTION BOX
BLWR
N
INDOOR
AIR CLEANER
HUM
DOOR
NEUTRAL
INT
EG
RA
TE
D CO
NT
RO
L M
O
DUL
E
TO 115VAC/ 1Ø /60 HZ POWER SUPPLY WITH
115 VAC
HUM-OUT
IGNITER
CIRCULATOR
BEFORE SERVICING.
FLAME SENSOR
DISCONNECT POWER
LINE
GND
BL
BR
WH
PK
BK
BK
BL
OR
PK
RD
RD
BL
9
8
12
1
15
11
14
7
2
5
4
13
3
6
10
M
O
DUL
E
CO
NT
RO
L
IN
TEG
RA
TED
TW
O
-ST
AG
E
EAC
FS
BK
2
1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.
LIMIT CONTROL
AUXILIARY
AUTO RESET
WARNING:DISCONNECT
TRANSFORMER
40 VA
N
NO
3
BR
4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.
COLOR CODES:
1
E SWITCH
PRESSUR
SENSOR
FLAME
GN GREEN
GR
C
VAC
TO UNIT MUST BE
1
BR
AND GROUNDED.
1
115
SWITCH (PRESS.)
FIELD SPLICE
FIELD GND
LOW VOLTAGE FIELD
YL
LIMIT CONTROL
AUTO RESET PRIMARY
WH
1
RD RED
GY GRAY
AUTO RESET BURNER BOX
LIMIT
WH
L
NOTES:
PK
BK
5
SWITCH
ID BLOWER PRESSURE
OR
SERVICING. WIRING
EQUIPMENT GND
(ON SOME MODELS)
INTERNAL TO
PROT. DEVICE
INTEGRATED CONTROL
PK
C. USE COPPER CONDUCTORS ONLY.
$
AT LEAST 105
IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED,
BL
PLUG CONNECTION
2
4
BK
DOOR OPEN)
(OPEN WHEN
DOOR SWITCH
COMPARTMENT
BLOWER
SWITCH (TEMP.)
GND
C
BLOWER
CIRCULATOR
PU PURPLE
JUNCTION
40 VA
PK PINK
Ø /60 HZ
DISCONNECT
GAS VALVE
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.
OVERCURRENT
HI VOLTAGE (115V)
CONNECTOR
2 CIRCUIT
LOW VOLTAGE (24V)
GND
VAC
CHA
SS
IS
GR
OU
ND
2
3
4
IGNITER
SURFACE
HOT
2
GND
BK BLACK
SETUP IS DONE WITHIN COMMUNICATING THERMOSTAT)
LEGACY MODE) OR INDEPENDENTLY FROM HEAT CALL (COMMUNICATING MODE ONLY -
TERMINALS TO RUN HUMIDIFIER DURING HEAT CALL ( COMMUNICATING MODE OR
HEAT CALL (COMMUNICATING OR LEGACY MODES). USE HUM-IN AND HUM-OUT
6. HUMIDIFIER INSTALLATION OPTIONS: USE HUM TERMINAL TO RUN HUMIDIFIER DURING
FOR MORE THAN 2 SECONDS WHILE IN STANDBY (NO THERMOSTAT INPUTS)
5. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH
INDUCTOR COIL
BL BLUE
M
BLOWER
DRAFT
INDUCED
WH WHITE
BK
24
BLOWER COMPARTMENT
115 VAC/ 1
OVERCURRENT
BK
BR BROWN
YL YELLOW
3
HI VOLTAGE FIELD
HARNESS
ECM MTR
OR ORANGE
TERMINAL
POWER BEFORE
IGNITER
RD
BK
TO
RD
POWER SUPPLY WITH
BURNER COMPARTMENT
PROTECTION DEVICE
PROPERLY POLARIZED
WH
BK
JU
NC
TION
B
OX
GR
GND
BL
GY
RD
IGN
IND
-HI
IND
-LO
IND
-N
IGN
-N
MOB_PE
AUX
IN
AUX
OUT
3A
FU
SE
1 2 R C
BIA
S
BIA
S
BIA
S
BIA
S
TER
M
R C G W Y
DH
Y2
SAT
GND
GND
NA
RAT
TER
M
CT
BREAK OFF
TABS
DATA AC
BREAK OFF
TABS
LEFT CENTER RIGHT
ST
AT
US
COD
E
BL
BR
PU
UV
W
LINE
NE
UT
RA
L
BK
BL
GY
BK
RD
YL
WH
RD
BK
BK
WH
WH
WH
GND
TX
RX
BR
RD
WH
WH
WH
RD
GN
YL
GN
BL
BR
BL
VDD
BL
OR
BR
GN
PK
OR
BL
BR
OR
BR
BL
(3)
(1)
M
C
GND
E34
GND
GV (13)
(8)
PRESSURE
TRANSDUCER
PT (3)
PT (1)
PT (2)
+-
O
PR
ES
SU
RE
TR
ANS
DU
CE
R
BK
RD
GN
2
1
3
BR
BL
R
GN
BK
C
SWITCH
PRESS.
NO
PU