7-22
PROBLEM - E:
Unit does not heat up even if display counts down when
START key is touched for HIGH POWER cooking.
Check: 1. PRIMARY AND SECONDARY INTERLOCK SWITCHES
2. THERMOSTAT
1
2
Runs
Runs
Runs
Contact
OK
NO
continuity
Replace
circuit board
Normal
circuit board
Poor contact
Replace
circuit board
Normal
circuit board
Contact OK
Normal
contact
Correct
seating
Check contact of
connector
Check the contact of
relay 7 (see page 7-15)
Resistance
incorrect
Check the continuity of
H.V
.C. (see page 7-15)
Normal H.V
.T
.
Resistance
incorrect
Normal H.V
.C.
Abnormal
Replace H.V
.D.
Normal
Magnetron
Replace
Magnetron
Normal
Normal
H.V
.D.
Check the
continuity of H.V
.D.
(see page 7-15)
Replace H.V
.C.
Normal
resistance
Replace H.V
.T
.
Normal
resistance
Runs
Runs
Runs
Runs
Measure resistance of
H.V
.T
ransformer
(see page 7-14)
Содержание AMV4204AAB
Страница 9: ...5 1 OVERALL CIRCUIT DIAGRAM SCHEMATIC DIAGRAM I Check the Model No ...
Страница 10: ...5 2 SCHEMATIC DIAGRAM II Check the Model No ADD Noise filter ...
Страница 11: ...5 3 MATRIX CIRCUIT FOR TOUCH KEY BOARD 13 12 8 9 10 11 2 1 3 4 5 6 7 KEY MATRIX ...
Страница 37: ...8 2 CONTROLLER PARTS 2004 2002 2381 2008 2006 2009 W130 2000 07 Check the Serial No EV ...
Страница 39: ...8 4 LATCH BOARD PARTS W111 4004 4003 4002 4002 4001 4000 EV ...
Страница 43: ...8 8 INSTALLATION PARTS VINYL BAG 6011 6009 6010 6008 EV ...
Страница 44: ...P NO 3828W5S3657 Printed in Korea ...