background image

SS-AMVM97

www.amana-hac.com

10/17

Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P., Houston, Texas.

Supersedes 2/17

M

odulating

, V

ariable

-S

peed

  

eCM g

aS

 F

urnaCe

 u

p

 

to

 98% aFue

H

eating

 i

nput

:  60,000–120,000 Btu/

H

*  Complete warranty details available from your local dealer or at www.amana-hac.com. To receive the Lifetime Heat Exchanger 

Limited Warranty, the Lifetime Unit Replacement Limited Warranty (in both cases good for as long as you own your home), and 
the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not 

required in California or Québec.

Standard Features

Cabinet Features

• 

ComfortNet™ Communicating System compatible

• 

Heavy-duty stainless-steel tubular heat exchanger 

• 

Stainless-steel secondary heat exchanger

• 

Self-calibrating modulating gas valve 

 

auto-configure for each installation 

• 

Durable Silicon Nitride igniter

• 

Quiet two-speed induced draft blower

• 

Uses ComfortNet™ communicating, 

 

two-stage or single-stage thermostats

• 

Self-diagnostic control board with constant memory 
fault code history output to a dual 7-segment display

• 

Color-coded low-voltage terminals with provisions 

 

for electronic air cleaner and humidifier

• 

Efficient and quiet variable-speed airflow system gently 

 

ramps up or down according to heating or cooling demand

• 

Multiple continuous fan speed 

 

options offer quiet air circulation

•  Auto-Comfort and enhanced  

dehumidification modes available

• 

All models comply with California 40 ng/J 

 

Low NOx emissions standard

• 

Designed for multi-position installation:

 

AMVM97: upflow, horizontal left or right 

 

ACVM97: downflow, horizontal left or right 

• 

Certified for direct vent (2-pipe) 

 

or non-direct vent (1-pipe) 

• 

Easy-to-install top venting 

 

with optional side venting

• 

Convenient left or right connection 

 

for gas and electrical service

• 

Cabinet air leakage (Q

Leak

) ≤ 2% 

• 

Heavy-gauge steel cabinet with durable finish

• 

Fully insulated heat exchanger 

 

and blower section

• 

Airtight solid bottom or side return 

 

with easy-cut tabs for effortless removal 

 

in bottom air-inlet applications

Contents

Nomenclature ........................................

2

Product Specifications

 ........................... 3

Dimensions ............................................ 4

Airflow Specifications

 ............................

6

Wiring Diagram

 .................................... 11

Accessories ..........................................

12

AMVM97 / ACVM97

Содержание ACVM97

Страница 1: ...g two stage or single stage thermostats Self diagnostic control board with constant memory fault code history output to a dual 7 segment display Color coded low voltage terminals with provisions for e...

Страница 2: ...trol Configuration NOx M Upflow Horizontal N Low NOx C Downflow Horizontal Cabinet Width Motor B 17 C 21 V Variable Speed ECM ComfortNet D 24 E Multi Speed ECM S Single Speed Maximum CFM 2 800 CFM 4 1...

Страница 3: ...on System ICS Installer must supply one or two PVC pipes one for combustion air optional and one for the flue outlet required Vent pipe must be either 2 or 3 in diameter depending upon furnace input n...

Страница 4: ...0 19 20 5 9 19 34 19 B C 23 2 1 2 2 6 5 9 19 23 24 31 A 21 2 14 23 1 1 28 2 1 2 2 2 6 1 26 23 Folded Flanges 22 Unfolded Flanges D Unfolded Flanges E Folded Flanges Air Discharge Air Discharge LEFT SI...

Страница 5: ...nstallation on non combustible floors only A combustible floor sub base must be used for installations on combustible flooring 18 A 34 4 11 14 25 B Return 28 C 6 6 11 14 14 25 3 2 2 1 2 23 14 1 1 1 1...

Страница 6: ...mal 1 316 55 Plus 10 887 594 Plus 10 1 448 50 C Minus 10 921 635 C Minus 10 1 250 57 Normal 1 023 705 Normal 1 389 52 Plus 10 1 125 776 Plus 10 1 528 47 D Minus 10 1 107 737 D Minus 10 1 256 57 Normal...

Страница 7: ...F A Minus 10 780 492 A Minus 10 1 702 63 Normal 867 547 Normal 1 891 57 Plus 10 954 602 Plus 10 2 080 52 B Minus 10 1 044 748 B Minus 10 1 746 62 Normal 1 160 831 Normal 1 940 56 Plus 10 1 276 914 Plu...

Страница 8: ...c ESP ACVM970803BNA Heating Speed 1 5 w c ESP Rise Range 35 65 F Tap Adjust High Stage CFM Low Stage CFM Tap Adjust High Stage CFM Rise F A Minus 10 562 365 A Minus 10 950 n a Normal 624 405 Normal 1...

Страница 9: ...e F A Minus 10 706 472 A Minus 10 1 583 57 Normal 784 524 Normal 1 759 51 Plus 10 862 576 Plus 10 1 935 46 B Minus 10 970 670 B Minus 10 1 617 56 Normal 1 078 744 Normal 1 797 50 Plus 10 1 186 818 Plu...

Страница 10: ...TU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1 08 CFM 800 T...

Страница 11: ...TO 60HZ 115 VAC 1 POWER SUPPLY WITH POWER BEFORE SERVICING WIRING TO UNIT MUST BE TO UNIT MUST BE PROPERLY POLARIZED EQUIPMENT GND FIELD SPLICE SWITCH TEMP SWITCH PRESSURE PROT DEVICE LOW VOLTAGE FIEL...

Страница 12: ...manent Filter 0170K00000S Flush Mount Vent Kit 3 or 2 0170K00001S Flush Mount Vent Kit 2 AFE18 60A Fossil Fuel Dual Fuel Kit LPLP03 Low LP Gas Pressure Switch LPM 09 LP Conversion Kits Notes Indicates...

Отзывы: