background image

8

www.amana-hac.com

SS-

AMVM97

SS-

AMVM97

www.amana-hac.com

9

ACVM970603BNA

Cooling Speed 

(@ .1" - .8" w.c. ESP)

ACVM970603BNA

Heating Speed

(@ .1" - .5" w.c. ESP; Rise Range:  35 - 65°F)

Tap

Adjust

High-Stage

CFM

Low-Stage

CFM

Tap

Adjust

High-Stage

CFM

Rise

(°F)

A

Minus 10%

590

390

A

Minus 10%

844

64

Normal  

656

433

Normal  

938

57

Plus 10%

722

476

Plus 10%

1,032

52

B

Minus 10%

711

487

B

Minus 10%

855

63

Normal  

790

541

Normal  

950

57

Plus 10%

869

595

Plus 10%

1,045

52

C

Minus 10%

875

617

C

Minus 10%

887

61

Normal  

972

686

Normal  

986

55

Plus  10%

1,069

755

Plus 10%

1,085

50

D

Minus 10%

1,076

725

D

Minus 10%

893

60

Normal  

1,195

806

Normal  

992

54

Plus 10%

1,315

887

Plus 10%

1,091

49

ACVM970803BNA

Cooling Speed 

(@ .1" - .8" w.c. ESP)

ACVM970803BNA

Heating Speed

(@ .1" - .5" w.c. ESP; Rise Range:  35 - 65°F)

Tap

Adjust

High-Stage

CFM

Low-Stage

CFM

Tap

Adjust

High-Stage

CFM

Rise

(°F)

A

Minus 10%

562

365

A

Minus 10%

950

n/a

Normal  

624

405

Normal  

1,056

n/a

Plus 10%

686

446

Plus 10%

1,162

62

B

Minus 10%

727

494

B

Minus 10%

1,031

n/a

Normal  

808

549

Normal  

1,146

63

Plus 10%

889

604

Plus 10%

1,261

57

C

Minus 10%

895

610

C

Minus 10%

1,130

64

Normal  

994

678

Normal  

1,256

57

Plus 10%

1,093

746

Plus 10%

1,382

52

D

Minus 10%

1,059

706

D

Minus 10%

1,214

59

Normal  

1,177

784

Normal  

1,349

53

Plus 10%

1,295

862

Plus 10%

1,484

48

ACVM97 Airflow Data

Notes

• 

All furnaces ship as high speed for cooling.  Installer must adjust blower 

 

speed as needed.

• 

For most jobs, about 400 CFM per ton when cooling is desirable.

• 

INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE

.

Содержание ACVM97

Страница 1: ...g two stage or single stage thermostats Self diagnostic control board with constant memory fault code history output to a dual 7 segment display Color coded low voltage terminals with provisions for e...

Страница 2: ...trol Configuration NOx M Upflow Horizontal N Low NOx C Downflow Horizontal Cabinet Width Motor B 17 C 21 V Variable Speed ECM ComfortNet D 24 E Multi Speed ECM S Single Speed Maximum CFM 2 800 CFM 4 1...

Страница 3: ...on System ICS Installer must supply one or two PVC pipes one for combustion air optional and one for the flue outlet required Vent pipe must be either 2 or 3 in diameter depending upon furnace input n...

Страница 4: ...0 19 20 5 9 19 34 19 B C 23 2 1 2 2 6 5 9 19 23 24 31 A 21 2 14 23 1 1 28 2 1 2 2 2 6 1 26 23 Folded Flanges 22 Unfolded Flanges D Unfolded Flanges E Folded Flanges Air Discharge Air Discharge LEFT SI...

Страница 5: ...nstallation on non combustible floors only A combustible floor sub base must be used for installations on combustible flooring 18 A 34 4 11 14 25 B Return 28 C 6 6 11 14 14 25 3 2 2 1 2 23 14 1 1 1 1...

Страница 6: ...mal 1 316 55 Plus 10 887 594 Plus 10 1 448 50 C Minus 10 921 635 C Minus 10 1 250 57 Normal 1 023 705 Normal 1 389 52 Plus 10 1 125 776 Plus 10 1 528 47 D Minus 10 1 107 737 D Minus 10 1 256 57 Normal...

Страница 7: ...F A Minus 10 780 492 A Minus 10 1 702 63 Normal 867 547 Normal 1 891 57 Plus 10 954 602 Plus 10 2 080 52 B Minus 10 1 044 748 B Minus 10 1 746 62 Normal 1 160 831 Normal 1 940 56 Plus 10 1 276 914 Plu...

Страница 8: ...c ESP ACVM970803BNA Heating Speed 1 5 w c ESP Rise Range 35 65 F Tap Adjust High Stage CFM Low Stage CFM Tap Adjust High Stage CFM Rise F A Minus 10 562 365 A Minus 10 950 n a Normal 624 405 Normal 1...

Страница 9: ...e F A Minus 10 706 472 A Minus 10 1 583 57 Normal 784 524 Normal 1 759 51 Plus 10 862 576 Plus 10 1 935 46 B Minus 10 970 670 B Minus 10 1 617 56 Normal 1 078 744 Normal 1 797 50 Plus 10 1 186 818 Plu...

Страница 10: ...TU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1 08 CFM 800 T...

Страница 11: ...TO 60HZ 115 VAC 1 POWER SUPPLY WITH POWER BEFORE SERVICING WIRING TO UNIT MUST BE TO UNIT MUST BE PROPERLY POLARIZED EQUIPMENT GND FIELD SPLICE SWITCH TEMP SWITCH PRESSURE PROT DEVICE LOW VOLTAGE FIEL...

Страница 12: ...manent Filter 0170K00000S Flush Mount Vent Kit 3 or 2 0170K00001S Flush Mount Vent Kit 2 AFE18 60A Fossil Fuel Dual Fuel Kit LPLP03 Low LP Gas Pressure Switch LPM 09 LP Conversion Kits Notes Indicates...