background image

PRODUCT IDENTIFICATION

2

The model and manufacturing number are used for positive identification of component parts used in manufacturing.
Please use these numbers when requesting service or parts information.

WARNING

WARNING

HIGH VOLTAGE!

Disconnect ALL power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal
injury or death.

Installation and repair of this unit
should be performed ONLY by indi-

viduals meeting the requirements of an "entry level tech-
nician", at a minimum, as specified by the Air-Conditioning,
Heating, and Refrigeration Institute (AHRI).  Attempting to
install or repair this unit without such background may
result in product damage, personal injury or death.

Goodman will not be responsible
for any injury or property damage

arising from improper service or service procedures. If
you install or perform service on this unit, you assume
responsibility for any personal injury or property damage
which may result. Many jurisdictions require a license to
install or service heating and air conditioning equipment.

WARNING

WARNING

WARNING

WARNING

*

M

S

S

9

2

0

6

0

3

B

N

A

A

1

2

3

4

5

6

7

8

9

10

11

12

13

14

Brand

Minor Revision

A- Amana® Brand  G- Goodman® Brand

   A - Initial Release
   B - 1st Revision

Configuration
   M - Upflow/Horizontal

Major Revision

   C - Downflow/Horizontal

   A - Initial Release

   K - Dedicated Upflow

   B - 1st Revision

   D - Dedicated Downflow

Nox

Airflow

   N - Natural Gas

   C - Variable Speed/ComfortNet

   X - Low Nox

   E - High Efficiency 
   S - Single Speed

Cabinet Width
   A - 14"

Gas Valve Stages

   B - 17.5"

   M - Modulating

   C - 21"

   V - 2 Stage 

   D - 24.5"

   H - Convertible 2 Stage
   S - Single Stage

Maximum CFM
   3 - 1200 CFM

AFUE

   4 - 1600 CFM

   92 - 92% AFUE

   5 - 2000 CFM

MBTU/h
  040 - 40,000
  060 - 60,000
  080 - 80,000
  100 - 100,000
  120 - 120,000

Содержание ACSS920402BN

Страница 1: ...ED GAS FURNACE UP TO 92 AFUE Refer to Service Manual RS6612012 for installation operation and troubleshooting information All safety information must be followed as provided in the Service Manual Refe...

Страница 2: ...ble for any injury or property damage arising from improper service or service procedures If you install or perform service on this unit you assume responsibility for any personal injury or property d...

Страница 3: ...sions If a furnace or air handler is installed in an enclosed area and a carbon monoxide producing device is operated therein there must be adequate direct outside ventilation Carbon monoxide emission...

Страница 4: ...OR LEFT SIDE PVC VENT FLUE PIPE 2 PVC ALTERNATE VENT FLU E LOCATIO N RIGHT SIDE DRAIN TRAP EXTERIOR HOLES HIGH VOLTAGE ELECTRICAL OUTLE T ALTERNATE GAS SUPPL Y LOW VOLTAGE ELECTRICAL OUTLE T STANDARD...

Страница 5: ...18 1 8 17 1 2 18 19 1 2 CSS921005CN 21 18 1 8 17 1 2 18 19 1 2 A 34 4 11 14 25 28 C 6 6 11 14 14 25 3 2 2 1 2 23 14 1 1 1 E UNFOLDED FLANGES D FOLDED FLANGES 18 FOLDED FLANGES 20 UNFOLDED FLANGS 2 1 2...

Страница 6: ...ervice Connection FPT For bottom return Failure to unfold flanges may reduce airflow by up to 18 This could result in performance and noise issues Installer must supply one or tw o PVC pipes one for c...

Страница 7: ...supply one or tw o PVC pipes one for combustion air optional and one for the flue outlet required Vent pipe must be either 2 or 3 in diameter depending upon furnace input number of elbow s length of...

Страница 8: ...d Lo 3 5 1 565 54 1 545 55 1 529 56 1 487 57 1 441 59 1 365 1 287 1 196 Low 3 1 261 N A 1237 N A 1 242 N A 1 216 N A 1 179 N A 1 145 1 098 1 034 High 5 2 137 40 2 073 41 2 031 42 1 949 44 1 879 45 1 8...

Страница 9: ...58 1 390 61 1 320 1 205 1 083 Med Lo 3 0 1 632 52 1 546 55 1 493 57 1 415 60 1 332 64 1 257 1 148 1 054 Low 2 5 1 429 60 1 380 62 1 334 64 1 258 N A 1 199 N A 1 136 1 041 942 at 0 5 ESP Notes All furn...

Страница 10: ...LLING THIS UNIT MULTIPLE POWER SOURCES MAY BE PRESENT FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE PERSONAL INJURY OR DEATH 10 WIRING DIAGRAMS Wiring is subject to change Always refer to the wiring diag...