Component Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
RS5320016 Rev. 0
12
H.V. board
Pin 1
E1
E2
E3
J5
J1
J2
E4
E5
J3
J4
E7
E6
J7
J6
J8
Pin 28
Pin 1
Pin 1
Pin 1
Pin 1
Pin 1
Pin 1
Pin 1
Pin 50
Clip
Clip
Clip
Clip
Clip
Clip
Clip
In straight convection mode, both elements operate simultaneously.
In combination mode, the rear element will operate simultaneously with either the microwave or front element.
Function Test
Set-Up
Meter
Setting
Probe Placement
Results
Input to H.V. board
At H.V. board
Volts
J1 pin 1 (Black wire)
& J1 pin 2 (Red wire)
Line voltage
Output to display
board
Disconnect
J5 connector
Volts
J5 pin 28 &
J5 pin 50
-
24 VDC
NOTE: For the following test, place oven in Service Test Mode (see page 27).
Relay Function Test
Set-Up Meter
Setting
Probe Placement
Results
K1
Cooling fan
Disconnect
J2 connector
Ohms
J1 pin 1 (Black wire)
& J2 pin 4
Test mode 5 off
-
no continuity
Test mode 5 on
-
< 1
Ω
K2 Convection
motor
Disconnect
J2 connector
Ohms
J1 pin 1 (Black wire)
& J2 pin 3
Test mode 4 off
-
no continuity
Test mode 4 on
-
< 1
Ω
K3
Cavity light
Disconnect
J2 connector
Ohms
J2 pin 1
& J2 pin 2
Test mode 6 off
-
no continuity
Test mode 6 on
-
< 1
Ω
K4
Heater A
(front)
Disconnect
J3 connector
Ohms
E4 & J3 pin 3
Test mode 2 off
-
no continuity
Test mode 2 on
-
< 1
Ω
K7 Microwave
Disconnect
J4 connector
Ohms
J4 pin 4 &
J4 pin 5
Test mode 3 off
-
no continuity
Test mode 3 on
-
< 1
Ω
K9
Heater B
(rear)
Disconnect
J4 connector
Ohms
E6 & J4 pin 1
Test mode 1 off
-
no continuity
Test mode 1 on
-
< 1
Ω