To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit and
discharge capacitor through a 10,000 ohm resistor before attempting to service, unless test procedures
require power to be connected. Ensure all ground wires are connected before certifying unit as repaired
and/or operational.
©2003 Maytag Appliances Company
16022379 Rev. 0
19
Disassembly Procedures
Front Frame Removal
To remove front frame:
1. Remove Air Filter (See Air Filter Removal).
2. Remove Temperature and control knobs.
3. Remove 1 screw securing front frame to air
conditioner chassis.
4. Pull front frame out and away from air conditioner.
Screw
Outer Case Removal
To remove outer case:
1. Remove 8 screws securing outer case to chassis.
2. Remove outer case by spreading and lifting case
off of chassis.
Screws
Screws