![AMALGAMATED INSTRUMENT LC-CL Series Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/amalgamated-instrument/lc-cl-series/lc-cl-series_manual_2915951039.webp)
4.94
Baud rate for optional serial communications
Display:
bAUd RAtE
Range:
300, 600, 1200, 2400, 4800, 9600, 19.2
or
38.4
Default Value:
9600
Select from
300,600,1200,2400,4800,9600,19.2
or
38.4
baud. This must be set to match the
baud rate selected at the sending device.
4.95
Parity for serial input
Display:
PrtY
Range:
NONE, EUEN
or
Odd
Default Value:
NONE
Select parity check to either
NONE
,
EUEN
or
Odd
. This must be set to match the parity selected at the
sending device.
4.96
Data type
Display:
dAtA
Range:
8.bit
or
7.bit
Default Value:
8.bit
Displays and selects the input data type. Select either
8.bit
for 8 data bits plus 1 stop bit or
7.bit
for
7 data bits plus 1 stop bit. This must be set to match the number of data bits of the sending device.
4.97
Serial communications type
Display:
SER.1 tYPE
Range:
NONE, R232
or
R485
Default Value:
NONE
Selects the serial output communications type from:
NONE
for no serial output,
R232
for RS232 output
or
R485
for RS485 output. Note that the serial output is optional and factory configured with the
hardware for one particular type of output i.e. if fitted with RS232 hardware then both the
SER.1 tYPE
and the hardware must be changed to convert to RS485.
4.98
Serial communications type for second comms. port
Display:
SER.2 tYPE
Range:
NONE, R232
or
R485
Default Value:
NONE
Not applicable to this model - leave this function set to
NONE
.
LDRSMANADD-2.3-0
39 of