MAWA-050A
2. Installation and Connections
2-32
- The SCH signal is not input when “4. (6)
(c) SCH & Torch select by I/O” is set to ON.
*2: When “4. (6)
(a) NG judgment error” is set to ON and the welding result is LOST, “E05 Weld
error” and “E10 LOST error” occur and the 06. LOST is output. In this case, the 06. LOST
output is turned off when the “RESET” operation is performed.
*3: Can be output from the output connector of this product by setting each signal of the optional
touch start head controller to user output.
*4: Applied by a combination of the foot switch cable 2 (SK-1202978) and the software version of
the head controller V00-03A or later. The touch start head passes without stopping at the
mid-point, the MID POINT output time becomes 1 ms or less.
*5: As the timing chart in 6. (7)
, the H-ST1 output (user signal) is output for the time set in
“START signal input decision delay time.”