MAWA-050A
4. Explanation of Screens
4-43
(19) Set Values of Each Screen at Delivery from the Factory
The following table shows initial set values of each screen at delivery from the factory. When the
memory was initialized on the Switch select screen, these initial values are provided.
Screen Parameter
Initial
value
Basic setting
screen
Device No.
1
Language selection
English
Brightness adjustment
08
EX comm type
OFF
Communication speed
9600
Internal resistance
OFF
Switch select
screen
NG judgment error
OFF
Start parity error ON/OFF
OFF
SCH & Torch select by I/O
OFF
Measurement current select
RMS
Measurement voltage select
RMS
Enable START switch
ON
Internal Gas Flow
ON
High speed SCH change (No Wave)
OFF
Fine Weld Mode
OFF
Torch drive type
MOTOR
GOOD/NG signal output time
200 [ms]
END signal output time
200 [ms]
START signal input delay time
20 [ms]
SCH changeover delay time
20 [ms]
TORCH changeover delay time
20 [ms]
H-END output time
200 [ms]
H-RESET output time
200 [ms]
H-HEAD UP output time
200 [ms]
ALL-WELD count
0
External I/O
setting screen
User input terminal 1
00: Not selected
User input terminal 2
00: Not selected
User output terminal 1
06: LOST
User output terminal 2
05: READY
User output terminal 3
03: END
User output terminal 4
07: WEL1 LOWER CURRENT
User output terminal 5
08: WEL1 UPPER CURRENT
User output terminal 6
17: WEL2 LOWER CURRENT
User output terminal 7
18: WEL2 UPPER CURRENT