
MAWA-050A
7. External Communication Function
7-14
Command 10 (welding result) Common data (Condition No.: 000)
Welding result check (data reading only: MAWA-050A
→
Host computer)
Welding result data by the latest welding conditions is read.
Item Contents
Character
string
Range
1
Torch No.
nn,
01 ~ 02
2
Welding result
nn,
01: GOOD 02: NG 03: LOST
3
WELD1 current
nn.nn,
00.00 ~ 99.00 (A)
4
WELD1 voltage
nn.nn,
00.00 ~ 99.99 (V)
5
WELD1 time
nnnn.n,
0000.0 ~ 9999.0 (ms)
6
WELD2 current
nn.nn,
00.00 ~ 99.00 (A)
7
WELD2 voltage
nn.nn,
00.00 ~ 99.99 (V)
8
WELD2 time
nnnn.n,
0000.0 ~ 9999.0 (ms)
9 ALL
COUNT
nnnnnn,
000000 ~ 999999
10
TORCH 1 preset count
nnnnnn,
000000 ~ 999999
11
TORCH 1 workpiece count
nnnnn,
00000 ~ 60000
12
TORCH 1 weld count
nnn,
000 ~ 255
13
TORCH 2 preset count
nnnnnn,
000000 ~ 999999
14
TORCH 2 workpiece count
nnnnn,
00000 ~ 60000
15
TORCH 2 weld count
nnn
000 ~ 255