Pega 367 with Fanuc 04PC User Pre-installation Guide
©Amada America, Inc.
Print Date 03/07/2001 Revision 4.0
This document available on the World Wide Web at http://www.amada.com
Page 29 of 35
Y AXIS BALL SCREW
X AXIS BALL SCREW
Y AXIS LM GUIDES (1 EACH SIDE)
X AXIS LM GUIDES (TOP AND BOTTOM)
UPPER AND LOWER TURRETS
Removing the Protective Coating
The Pega 367 must be thoroughly cleaned of protective coating. The sheet metal guards can be removed from around the
turret to allow cleaning of the upper and lower turrets, tool bores and die holders.
Please note the following:
!
Remove wrapping paper from the X and Y-axes
ball screws, then remove the protective coating.
!
Remove the wrapping paper from the X and Y
LM guides then remove the protective coating,
make sure that you remove the paper from both
sides of the carriage.
!
Clean die holders one at a time. Remove a die
holder, clean and replace it before removing the
next die holder. If the die holders are mixed up,
serious turret alignment problems may occur.
!
A suitable solvent should be used to remove the
protective coating.