MM-315B
5. Measurement
5-8
c. Setting of the First Cycle
Now press the
(+456
%;%
button.
Press
(+456
%;%
.
L
o
0
1
0
1
The cursor moves to FIRST CYC. Press
㧗
and set the First Cycle to 3.
Press
㧗
.
L
o
0
1
0
1
↓
L
o
0
1
0
2
↓
L
o
0
1
0
3
The First Cycle is set to the 3rd cycle.
To measure weld the current, press the
%744
&')
button to show the initial
display.
When the First Cycle is set to 3, if the following current is supplied, the measured
interval will be as follows:
Measurement starts at the third cycle; the first and second cycles are ignored. With
the above procedure, measurement settings are complete.
To measure the weld current, be sure to press the
%744
&')
button to show the
initial display.
I
31
+ I
32
+ I
41
+ I
42
+ I
51
+ I
52
+ I
61
+ I
62
8
=
Cycles
Measurement interval
Displayed current
Average true values