3. INSTALLATION 

3.1. 

Unpacking and Inspection 

Examine the Limousin UPS packaging for damage.  Inform the carrier 
immediately if and/or when damage is noticed.  Retain the packaging for 
future use. 
 

3.2. Placement 

Install the Limousin UPS in a protected area with adequate airflow, free of 
excessive dust and other airborne particles.  Allow for air circulation 
through the Limousin UPS.  A minimum clearance of 10cm is required on 
all sides.  Do not operate the Limousin UPS where the temperature and 
humidity is outside the specified limits. 

 

3.3. 

Connect to Utility 

Connect the included AC input power connector to utility power and the 
UPS system. 
 

3.4. 

Charging the Battery 

The UPS charges its battery whenever the UPS is in “LINE” mode.   

NOTE: For best results, initially charge the battery for 4 hours before 
connecting a load. 

 

3.5. 

Connecting the Load 

Plug the load into the power outlets on the rear of the Limousin UPS.  To 
use the UPS as a master on/off switch, make sure all of the loads 
connected to the UPS are switched on. 
 

 

CAUTION:  

Never connect a laser printer or plotter to the UPS with other computer 
equipment.  
 
A laser printer or plotter draws significantly more power when starting up 
than when idling.  The laser printer or plotter will overload the UPS on 
start up.  Thus, the UPS needs to be increased in size to accommodate the 
inrush of power if a laser printer or plotter

 

requires protection against 

blackouts, brownouts and over-voltage.

 

 

3.6. Storage 

Conditions 

Store the UPS upright, covered and in a cool, dry location, with its battery 
fully charged.  Before storing, charge the UPS for at least eight (8) hours.   
 

3.7. Extended 

Storage 

To store the Limousin UPS for extended periods, these instructions should 
be followed:  

1. 

In environments where the ambient temperature is -15 to 
+30

°

C (+5 to +86

°

F), charge the UPS battery every 6 months.  

2. 

In environments where the ambient temperature is +30 to 
+45

°

C (+86 to +113

°

F), charge the UPS battery every 3 

months.

 

Содержание Limousin II

Страница 1: ...Always On UPS Systems Inc Limousin II Single Phase Input Single Phase Output Uninterruptible Power Supply 600VA User Manual Version 1 4...

Страница 2: ...and performance of the UPS never load the UPS with a hair dryer heater laser printer or other types of inductive loads 9 The UPS has its own internal energy source battery therefore the output recepta...

Страница 3: ...Switching Off the UPS 4 4 3 Self Test 4 4 4 Silence the Alarm 4 4 5 Cold Start 4 4 6 Green Function 4 5 AUDIBLE ALARM 5 5 1 Back Up Slow Alarm 5 5 2 Low Battery Rapid Alarm 5 5 3 Overload Continuous...

Страница 4: ...eration of the UPS and the condition of the battery The Limousin provides two single phase 120VAC outlets for ease of connection to you equipment Overload protection is also a feature of this unit The...

Страница 5: ...or more than 3 seconds to turn the UPS ON or OFF press and hold the button less than 1 second to activate a self test or silence the back up alarm Figure 2 1 Limousin Front Rear Panel 2 2 Rear Panel 3...

Страница 6: ...load into the power outlets on the rear of the Limousin UPS To use the UPS as a master on off switch make sure all of the loads connected to the UPS are switched on CAUTION Never connect a laser print...

Страница 7: ...to on line operation On completion of the test the LED stops flashing and remains on If the UPS fails the self test it immediately returns to on line operation If a failure occurred recharge the batte...

Страница 8: ...test See replace battery section for battery replacement or call your dealer for services 6 SOFTWARE OPTIONS 6 1 UPSMON Software The UPSMON software uses the standard RS 232 interface to perform monit...

Страница 9: ...open files before the battery reserves are exhausted 3 The ability to turn off the UPS 4 The ability to make the UPS perform a self test Some computers are equipped with a serial connector to link wit...

Страница 10: ...r off and place it to the side The connecting wires and electronics will be exposed CAUTION Be careful not to touch any inner components of the Limousin UPS when changing the battery Electrical shock...

Страница 11: ...center to replace batteries UPS has no reaction while AC power is connected yet starts after pushing power on off switch Fuse at back panel burnt No AC input UPS AC detecting circuit fail Check power...

Страница 12: ...ealed Lead Acid Typical Recharge Time 4 hours to 90 of full capacity Protection Automatic self test discharge protection replace battery indicator BATTERY Back up Time 10 30 minutes depending on load...

Страница 13: ...nups com Website www alwaysonups com 10 2 QA Warranty Questions Always On UPS Systems Inc Bldg 1 150 Campion Road Kelowna BC Canada V1X 7S8 Phone 250 491 9777 Ext 209 Fax 250 491 9775 Email qa alwayso...

Отзывы: