background image

Always “On” UPS Systems Inc. 

 

i

SAVE THESE SAFETY INSTRUCTIONS  

1. 

This manual contains important instructions for the Limousin and should be followed during 
installation and maintenance of the UPS and batteries. 

2. 

The UPS contains voltages that are potentially hazardous.  Please contact our dealers or 
qualified personnel for service. 

3. 

Only personnel whom are knowledgeable with batteries and the required precautions should 
perform any servicing on the batteries. Keep unauthorized personnel away from batteries. 

4. 

Replace the batteries with the same model number, type and rating. 

5. 

CAUTION:

 Do not dispose of batteries in a fire. The batteries may explode. 

6. 

CAUTION:

 Do not open or mutilate the batteries. Contents of the batteries are toxic and 

especially harmful to the skin and eyes. 

7. 

CAUTION:

 A battery can present a risk of electrical shock and high short circuit current.  

The following precautions should be observed when working on or with the batteries. 

− 

Remove watches, rings, or other metal objects. 

− 

Use tools with insulated handles. 

− 

Wear rubber gloves and boots. 

− 

Do not lay tools or metal parts on top of batteries. 

− 

Disconnect charging sources prior to connecting or disconnecting battery terminals. 

− 

Make sure batteries are not inadvertently grounded. If inadvertently grounded, remove 
source of ground. Contact with any part of a grounded battery can result in electric 
shock. The likelihood of a shock will be reduced if ground faults are removed during 
installation and maintenance (applicable to a UPS and a remote battery supply not 
having a grounded supply circuit).  

8. 

CAUTION:

 To ensure the safety and performance of the UPS, never load the UPS with a 

hair dryer, heater, laser printer or other types of inductive loads. 

9. 

The UPS has its own internal energy source (battery), therefore the output receptacles may 
have electricity present even though the UPS is disconnected from the utility power. 

10.  The DC voltage provided from the internal battery is 12VDC. 
11.  Isolated Ground Wire refers to the wire connecting electrical equipment to ground.  

The isolated ground wire (green or green with yellow stripe) must meet national wire 
requirements. 

12.  The utility plug (wall plug) for the UPS must be equipped with a ground prong. 
13.  To avoid explosions, keep open flame and other heat emitting sources away from 

batteries. 

14.  The battery has the potential to generate high voltages and currents that are dangerous.  

To maintain secure operation and performance of the UPS, the user must exercise 
regular basic maintenance.  Please follow the precautions below: 
1. 

Do not remove the UPS cover unless authorized by the factory.  Removing the 
cover will void the warranty. 

2. 

The UPS can only be connected to a 2-pole/3 wire plug. 

3. 

Do not install the UPS in an environment with excessive humidity. 

4. 

Do not allow liquids or foreign objects to penetrate inside the UPS. 

5. 

Allow for air circulation through the UPS.  A minimum clearance of 10cm is 
required on all sides. 

6. 

Do not overload the UPS with appliances such as a hair dryer, heater, vacuum, 
kettle, etc. 

7. 

Keep the UPS away from direct sunlight and heat-emitting sources. 

8. 

Install the UPS as close as possible to the load for maximum protection. 

10. Storage 

Requirements 

1. 

Recharge the UPS batteries every 6 months for no less than 8 hours at a time. 

2. 

In a high ambient temperature environment, recharge the UPS batteries every 3 
months for no less than 8 hours at a time

 

Содержание Limousin II

Страница 1: ...Always On UPS Systems Inc Limousin II Single Phase Input Single Phase Output Uninterruptible Power Supply 600VA User Manual Version 1 4...

Страница 2: ...and performance of the UPS never load the UPS with a hair dryer heater laser printer or other types of inductive loads 9 The UPS has its own internal energy source battery therefore the output recepta...

Страница 3: ...Switching Off the UPS 4 4 3 Self Test 4 4 4 Silence the Alarm 4 4 5 Cold Start 4 4 6 Green Function 4 5 AUDIBLE ALARM 5 5 1 Back Up Slow Alarm 5 5 2 Low Battery Rapid Alarm 5 5 3 Overload Continuous...

Страница 4: ...eration of the UPS and the condition of the battery The Limousin provides two single phase 120VAC outlets for ease of connection to you equipment Overload protection is also a feature of this unit The...

Страница 5: ...or more than 3 seconds to turn the UPS ON or OFF press and hold the button less than 1 second to activate a self test or silence the back up alarm Figure 2 1 Limousin Front Rear Panel 2 2 Rear Panel 3...

Страница 6: ...load into the power outlets on the rear of the Limousin UPS To use the UPS as a master on off switch make sure all of the loads connected to the UPS are switched on CAUTION Never connect a laser print...

Страница 7: ...to on line operation On completion of the test the LED stops flashing and remains on If the UPS fails the self test it immediately returns to on line operation If a failure occurred recharge the batte...

Страница 8: ...test See replace battery section for battery replacement or call your dealer for services 6 SOFTWARE OPTIONS 6 1 UPSMON Software The UPSMON software uses the standard RS 232 interface to perform monit...

Страница 9: ...open files before the battery reserves are exhausted 3 The ability to turn off the UPS 4 The ability to make the UPS perform a self test Some computers are equipped with a serial connector to link wit...

Страница 10: ...r off and place it to the side The connecting wires and electronics will be exposed CAUTION Be careful not to touch any inner components of the Limousin UPS when changing the battery Electrical shock...

Страница 11: ...center to replace batteries UPS has no reaction while AC power is connected yet starts after pushing power on off switch Fuse at back panel burnt No AC input UPS AC detecting circuit fail Check power...

Страница 12: ...ealed Lead Acid Typical Recharge Time 4 hours to 90 of full capacity Protection Automatic self test discharge protection replace battery indicator BATTERY Back up Time 10 30 minutes depending on load...

Страница 13: ...nups com Website www alwaysonups com 10 2 QA Warranty Questions Always On UPS Systems Inc Bldg 1 150 Campion Road Kelowna BC Canada V1X 7S8 Phone 250 491 9777 Ext 209 Fax 250 491 9775 Email qa alwayso...

Отзывы: