Always “On” UPS Systems Inc. 

 

1

 

Version 1.4

 

1. INTRODUCTION 

The Limousin is an economical UPS solution that provides ultimate protection for 
your home and office equipment from destructive problems that plague the utility.  
 
With the Limousin, you can expect brownout and surge protection with the AVR 
function using on-line voltage boost-up & buck-down. This allows for a wide input 
voltage range of 90 to 150VAC.  
 
After the UPS has been turned “On” it will protect the load from transients, spikes 
and other power aberrations.  In the event of a blackout (or severe brownout) the UPS 
will automatically switch to back-up mode. It will maintain power to the load until 
the battery reaches an exhausted state.  Also included, with our UPS systems, is a 
cyclic self-testing function to verify both the operation of the UPS and the condition 
of the battery. 
 
The Limousin provides two single-phase 120VAC outlets for ease of connection to 
you equipment. Overload protection is also a feature of this unit. 
 
The Limousin utilizes state-of-the-art microprocessor technologies to 
incorporate all these features into such a compact and convenient package.  
 

Interference to Radio/TV 

The Limousin may cause interference to radios and TVs in close proximity.  If 
you notice interference to radio or television reception, try turning the UPS off 
and on to see if the interference goes away. If so, the user is encouraged to try to 
correct the interference by one or more of following measures: 
 
1.  Move the Limousin and connected equipment to a different outlet. Check to 

make sure the new outlet is on a different power circuit than that of the 
radio/TV receiver. 

2.  Increase the separation distance between the Limousin and connected 

equipment, and the radio/TV receiver. 

3.  Re-orientate the receiving antenna. 

Содержание Limousin II

Страница 1: ...Always On UPS Systems Inc Limousin II Single Phase Input Single Phase Output Uninterruptible Power Supply 600VA User Manual Version 1 4...

Страница 2: ...and performance of the UPS never load the UPS with a hair dryer heater laser printer or other types of inductive loads 9 The UPS has its own internal energy source battery therefore the output recepta...

Страница 3: ...Switching Off the UPS 4 4 3 Self Test 4 4 4 Silence the Alarm 4 4 5 Cold Start 4 4 6 Green Function 4 5 AUDIBLE ALARM 5 5 1 Back Up Slow Alarm 5 5 2 Low Battery Rapid Alarm 5 5 3 Overload Continuous...

Страница 4: ...eration of the UPS and the condition of the battery The Limousin provides two single phase 120VAC outlets for ease of connection to you equipment Overload protection is also a feature of this unit The...

Страница 5: ...or more than 3 seconds to turn the UPS ON or OFF press and hold the button less than 1 second to activate a self test or silence the back up alarm Figure 2 1 Limousin Front Rear Panel 2 2 Rear Panel 3...

Страница 6: ...load into the power outlets on the rear of the Limousin UPS To use the UPS as a master on off switch make sure all of the loads connected to the UPS are switched on CAUTION Never connect a laser print...

Страница 7: ...to on line operation On completion of the test the LED stops flashing and remains on If the UPS fails the self test it immediately returns to on line operation If a failure occurred recharge the batte...

Страница 8: ...test See replace battery section for battery replacement or call your dealer for services 6 SOFTWARE OPTIONS 6 1 UPSMON Software The UPSMON software uses the standard RS 232 interface to perform monit...

Страница 9: ...open files before the battery reserves are exhausted 3 The ability to turn off the UPS 4 The ability to make the UPS perform a self test Some computers are equipped with a serial connector to link wit...

Страница 10: ...r off and place it to the side The connecting wires and electronics will be exposed CAUTION Be careful not to touch any inner components of the Limousin UPS when changing the battery Electrical shock...

Страница 11: ...center to replace batteries UPS has no reaction while AC power is connected yet starts after pushing power on off switch Fuse at back panel burnt No AC input UPS AC detecting circuit fail Check power...

Страница 12: ...ealed Lead Acid Typical Recharge Time 4 hours to 90 of full capacity Protection Automatic self test discharge protection replace battery indicator BATTERY Back up Time 10 30 minutes depending on load...

Страница 13: ...nups com Website www alwaysonups com 10 2 QA Warranty Questions Always On UPS Systems Inc Bldg 1 150 Campion Road Kelowna BC Canada V1X 7S8 Phone 250 491 9777 Ext 209 Fax 250 491 9775 Email qa alwayso...

Отзывы: