Chapter
3 - Commissioning
Table 3-3: CPE-ODU-PRO LEDs
Name
Description
Functionality
PWR
Power indication
Off – ODU is not powered
Green – ODU power is OK
ALARM Alarm
indication
Off – ODU is OK, diagnostic test passed
Red – ODU failure
ETH
Ethernet link status
indication
(Ethernet integrity)
Off – No Ethernet connectivity has been
detected between the outdoor unit and the
device connected to the indoor unit
Green– Ethernet connectivity has been
detected between the outdoor unit and the
device connected to the indoor unit
LINK QUALITY
bar display
Wireless link status and
signal quality Indication
* After power-up, the ALARM, ETH and all LINK QUALITY LEDs illuminate until
self-test is finished.
Table 3-4: CPE-ODU-PRO LINK QUALITY Bar LEDs Functionality
Bar LEDs
SNR
LED 1 (orange) is On
The SU is connected with and receives services from
AU/
µ
BST (Network Entry completed)
LED 2 (green) is On
5dB
≤
SNR < 10dB
LEDs 2-3 (green) are On
10dB
≤
SNR < 15dB
LEDs 2-4 (green) are On
15dB
≤
SNR < 20dB
LEDs 2-5 (green) are On
20dB
≤
SNR < 24dB
LEDs 2-6 (green) are On
SNR
≥
24 and RSSI < -75
LEDs 2-7 (green) are On
SNR
≥
24 and RSSI
≥
-75
LEDs 2-8 (green) are On
SNR
≥
24 and RSSI
≥
-70
LEDs 2-9 (green) are On
SNR
≥
24 and RSSI
≥
-60
LEDs 2-9 (green) and 10 (red) are On
RSSI
≥
-20 (saturation)
BreezeMAX PRO CPE
28
Содержание BreezeMAX PRO CPE
Страница 1: ...BreezeMAX BreezeMAX PRO CPE Manual S W Version 1 0 2 September 2005 P N 214094 ...
Страница 2: ......
Страница 8: ......
Страница 10: ......
Страница 12: ...Contents 4 10 SU Parameters Summary 55 Appendix A Preparing the SU IDU ODU Cable 57 BreezeMAX PRO CPE xii ...
Страница 14: ......
Страница 16: ......
Страница 17: ...1 1 Chapter 1 Product Description In This Chapter Introducing BreezeMAX PRO CPE page 2 Specifications page 4 ...
Страница 38: ......
Страница 46: ......
Страница 73: ...A A Appendix A Preparing the SU IDU ODU Cable ...