Chapter
2 - Installation
2.1.6 Connecting
the
Cables
2.1.6.1
Connecting the Grounding Cable
The Grounding screw (marked
╤
) is located on the bottom panel of the outdoor
unit.
To connect the grounding cable:
1
Connect one end of a grounding cable to the grounding screw and tighten the
grounding screw firmly.
2
Connect the other end of the grounding cable to a good ground (earth)
connection.
2.1.6.2
Connecting the Antenna Cable
To connect the RF cable (units with external antenna):
1
Connect one end of the coaxial RF cable to the RF connector (marked
)
located on the bottom panel of the unit.
2
Connect the other end of the RF cable to the antenna.
3
The RF connectors should be properly sealed to protect against rain and
moisture.
2.1.6.3
Connecting the SU’s IDU-ODU Cable
CAUTION
Use only Category 5E 4x2x24# FTP outdoor cables from an approved manufacturer. See list of
approved cables in Table
To connect the IDU-ODU cable:
1
Remove the two screws holding the waterproof service box to the outdoor unit
and remove the service box.
2
Unscrew the top nut from the service box.
3
Route a straight, uncrimped Category 5E Ethernet cable (8-wire, 24 AWG)
through both the top nut and the body of the service box.
4
Insert and crimp the RJ-45 connector. Refer to
for instructions on
preparing the cable.
5
Connect the Ethernet cable to the IDU COM RJ-45 connector.
BreezeMAX PRO CPE
16
Содержание BreezeMAX PRO CPE
Страница 1: ...BreezeMAX BreezeMAX PRO CPE Manual S W Version 1 0 2 September 2005 P N 214094 ...
Страница 2: ......
Страница 8: ......
Страница 10: ......
Страница 12: ...Contents 4 10 SU Parameters Summary 55 Appendix A Preparing the SU IDU ODU Cable 57 BreezeMAX PRO CPE xii ...
Страница 14: ......
Страница 16: ......
Страница 17: ...1 1 Chapter 1 Product Description In This Chapter Introducing BreezeMAX PRO CPE page 2 Specifications page 4 ...
Страница 38: ......
Страница 46: ......
Страница 73: ...A A Appendix A Preparing the SU IDU ODU Cable ...