SW1000 Installation and Operation Instructions
PUD3448R2-1
For Assistance: [email protected] +1 (909) 591-8431
Page 17
Open Entry
Open Exit
1
2
3
4
5
6
TB3
Common Ground
1
2
3
4
5
6
TB3
Common Ground
1. Locate the TB3 terminal block [Figure 14].
2. Connect wires to TB3-4 and common ground
(TB3-1 through TB3-3) [Figure 14].
Entry Passage Terminals
Figure 14
Exit Passage Terminals
Figure 15
Input signal must be a voltage-free, normally open,
momentary dry contact.
NOTE
Input signal must be a voltage-free, normally open,
momentary dry contact.
NOTE
1. Locate the TB3 terminal block [Figure 15].
2. Connect wires to TB3-6 and common ground
(TB3-1 through TB3-3) [Figure 15].
Terminal
Description
1 - 3
Common Ground
4
Entry Passage
5
Emergency Override
6
Exit Passage
Terminal
Description
1 - 3
Common Ground
4
Open Entry
5
Emergency Override
6
Open Exit
Receipt of an input contact opens the gate in
the entry direction for the defined dwell time,
then closes. Dwell time can be configured using
SwingGate Utility
. Typically, these signals are
provided after the access control system determines
the card presented at the gate is valid for entry, or a
integrated push button device is activated.
Receipt of an input contact opens the gate in the
exit direction for the defined dwell time, then closes.
Dwell time can be configured using
SwingGate
Utility
. Typically, these signals are provided
after the access control system determines the
card presented at the gate is valid for entry, or a
integrated push button device is activated.