8
6. WORKTIME SETTING
The limit settings of the motor should be made before the start of the working time setting procedure. The curtain must be
completely closed.
The maximum working time is 100 seconds (factory setting).
Procedure
LED D
Press the PB programming button (Figure 1)
lights green with a short blink
Press the
▲
button on the CB keyboard
flashes red
When fully opened, press
■
on the CB keypad
(can be pressed, for example, after ~3 seconds after full opening)
~2 seconds flashing green frequently
→
rarely flashes
green (control unit standby mode)
7. ADDING AND REMOVING REMOTE CONTROLS (AT-1, AT-1S, AT-15, AT-15S, AT-4N, etc.)
The control with the help of an added remote control is exercised as follows:
For UBS mode - control with three remote control buttons
▲
,
■
,
▼
«open», «stop», «close» respectively.
For SBS mode - control with button of the remote control in the sequence: «open - stop - close - stop - open - ...»
Adding remote controls
LED D
Press the PB programming button (Figure 1)
lights green with a short blink
Press the
▼
button on the CB keyboard
(Press the
▼
button as many times as necessary to select the re-
quired UBS or SBS control mode.)
flashes red once - UBS control mode
flashes red twice - SBS control mode (factory setting)
Press and release the remote control button
(For the UBS mode - press the button intended for opening, other
buttons are assigned automatically)
~2 seconds lights red
→
rarely flashes green
Press and release the same remote control button
~2 seconds lights red
→
rarely flashes green (control
unit standby mode)
If the remote button is reassigned, the recording procedure must be repeated.
Removing all remote controls
LED D
Press and hold (~ 9 seconds) PB programming button (Figure 1)
~ 9 seconds flashes green several times
→
red several
times
→
lights red
Release PB Programming Button
lights (~ 2 seconds) green
→
flashes quickly (~ 3 sec-
onds) red
→
rare green flashes (control unit standby)
If the button
■
is not pressed within 5 seconds after full opening, the control unit will retain the factory setting (100
seconds).
It is recommended to clear the control unit memory from previously recorded remote control codes before the first re-
mote control recording.
If the following action is not performed while adding a remote control unit for 6 seconds, the control unit will go into
standby mode (a rare flashing green light of the control unit indicator). The remote control will not be recorded and
the recording procedure must be performed again.
If the remote control is lost, in order to avoid unauthorized entry it is necessary to delete all remote controls from the
memory of the control unit and add them again.