background image

2

We reserve the right to any technical change. 

Valid on 2021.11.29

3. Technical specifications.

- Power supply: ~230V/50 Hz
- Power consumption: 0,4 W
- Fuse: 10 A
- Works with motors up to 230 Nm
- Frequency: 433.92 Mhz 
- Up to 12 transmitters can be programmed
- Operating temperature: ~ -20

o

C ~ +60

o

C

- Average range:  200 meters (in open space) 

 

 

35 meters (inside buildings)

- Dimensions: 93x57,5x26 mm 

 

Company reserves the tolerance of catalog data due the different conditions usage. 

Works with S, BD and M versions of tubular motors and can match all DC remote controllers.

5. Wiring diagram.

4. Layout of the elements.

1

3

4

5

6

2

7

8

1

 - Operating mode

2

 - Programming the direction of movement

3

 - Input / Output AC

4

 - LED diode (status)

5

 - Programming button

6

 - UP

7

 - STOP

8

 - DOWN

Input / Output 

AC

 

E               Protective wire  

L               230V AC supply – L wire (phase) 

N              230V AC supply – N wire (neutral) 

COM        Drive supply – N wire (joint) 

UP            Drive supply – L1 wire (UP direction) 

DOWN     Drive supply – L2 wire (DOWN direction)

Отзывы: