nuisance alarms, re-locate the Smoke 

Alarm further away where it will be less 

affected by cooking fumes etc. 

We recommend the use of a Heat 

Alarm in the Kitchen area to avoid such 

nuisance alarms.

7.3 Power Supply Monitoring
7.3.1 What to do when an Alarm is 

beeping:

A Smoke Alarm is beeping about every 

48 seconds with the yellow light flashing 

at the same time:

- Replace the Battery or Batteries.

7.3.2 Battery Replacement

When the battery power is low and 

replacement is necessary, the Smoke 

Alarm will “beep” and the yellow light 

will flash at the same time about once 

every 48 seconds for at least 7 days. 

The battery must then be replaced. 

Also, replace the battery if the Alarm 

does not sound when the Test Button is 

pressed. When you replace the battery 

you must press the Test button to check 

that the Alarm is functioning correctly. 

Only replace the battery with: Panasonic 

CR123A Batteries.

Dispose of used battery promptly.  Keep 

away from children.  Do not disassemble 

and do not dispose of in fire

Replacement batteries can be purchased 

at your local hardware store.

WARNING!

CONSTANT EXPOSURES TO HIGH 

OR LOW TEMPERATURES OR HIGH 

HUMIDITY MAY REDUCE BATTERY LIFE.

Use only batteries specified in marking. 

Use of a different battery may have a 

detrimental effect on Alarm operation.

These cells are intended for use at 

ordinary temperatures where anticipated 

high temperature excursions are not 

expected to exceed 100°C (212°F).

Prolonged periods of alarm will also 

reduce battery life.

Caution:  The battery used in this device 

may present a fire or chemical burn 

hazard if mistreated.  Do not recharge, 

disassemble, heat above 100°C (212°F) 

or dispose of in fire.  Replace battery 

with Panasonic CR123A, use of another 

battery may present a risk of fire or 

explosion.

7.4 Cleaning your Alarm

Clean your Alarm regularly. Use a soft 

bristle brush or the brush attachment of 

your vacuum cleaner to remove dust and 

cobwebs from the side slots where the 

smoke enters. To clean the cover, wipe 

with a damp cloth and dry thoroughly.

WARNING: Do not paint your Alarm.

Other than the maintenance and 

stop sounding shortly after the button is 

released. 

- Repeat this procedure for all other 

Alarms in the system.

** Pressing and holding the test button 

for six beeps will send fire alarm signal 

to panel**

WARNING:  Do not test with flame.

This can set fire to the Alarm and 

damage the house. We do not 

recommend testing with smoke as the 

results can be misleading unless special 

apparatus is used.

When you press the Test button it 

simulates the effect of smoke in a Smoke 

Alarm which it could experience in a real 

fire.

7.2 Test/Silence Button to Control 

Nuisance Alarms

The Smoke Alarms have a combined 

Test/Silence button to help you control 

nuisance/false alarms.

If, when the Alarm sounds, there is no 

sign of smoke or noise to indicate that 

there is a fire, it should be assumed that 

it is due to an actual fire and the dwelling 

should be evacuated immediately.

Check the house carefully in case there is 

a small fire smouldering somewhere.

Check whether there is some source of 

smoke or fumes, for example cooking 

fumes being drawn past the Alarm by an 

extractor.

If there are frequent nuisance/false 

alarms it may be necessary to re-locate 

the Smoke Alarm away from the source 

of the fumes.

If you installed Alarms with RF modules 

and did not House Code / enroll them in 

your system, you may be receiving alarm 

signals from a neighboring system. This 

can be easy rectified by “House Coding” 

your Alarms - see relevant RF Module 

Instruction booklet.

1. To cancel a false alarm from a Smoke 

Alarm (which has its red light flashing 

rapidly), press the Test/Silence button 

(the Smoke Alarm will automatically 

switch to a reduced sensitivity condition).

The Smoke Alarms will be silenced for 

a period of approximately 10 minutes. 

The red light on the cover of the Smoke 

Alarm will flash every 8 seconds to 

indicate that the unit has been silenced.

2. The Smoke Alarm will reset to normal 

sensitivity at the end of the silenced 

period (10 minutes). If additional silenced 

time is required, simply push the Test/

Silence button again.

3. If kitchen usage/layout is such that 

there are an unacceptable level of 

9

Содержание RE114

Страница 1: ...isted onto the smoke alarm 4 Remove the mounting plate and refer to Sections 2 and 6 for positioning and installation 5 After mounting plate is installed restore the smoke alarm onto the mounting plat...

Страница 2: ...s every 48 sec 2 Beeps End of Life Off 3 Flashes every 48 sec 3 Beeps Silence Sounding Alarm Press Release Button 1 Flash every 8 sec Off Off for 10 mins Silence End of Life indication up to 30 days P...

Страница 3: ...every level of a dwelling unit including basements 4 On every level of a residential board and care occupancy small facility including basements and excluding crawl spaces and unfinished attics 5 In t...

Страница 4: ...Smoke Alarms must be mounted away from corners Keep at least 305mm 12 from walls and corners see Figure 3 Additionally mount the unit at least 305mm 12 from any light fitting or decorative object whic...

Страница 5: ...ry replacement Locate the Alarm at least 1m 39 from dimmer controlled lights and wiring as some dimmers can cause interference Locate Alarm at least 1 5m 59 and route wiring at least 1m away from fluo...

Страница 6: ...press the test hush button Do not attempt to recharge or burn the battery as it may explode If it is necessary to remove the battery for separate disposal handle carefully to avoid possible eye damag...

Страница 7: ...the alarm sound or to those who may be incapable of safely evacuating the area unassisted Limitations of Heat Alarms There are various situations where a Heat Alarm may not be effective Fires where th...

Страница 8: ...essary it is possible to further secure the Alarm by using a No 2 or No 4 2 to 3mm 1 8 diameter not supplied self tapping screw 6 to 8mm 1 4 long see Figure 7d to firmly lock the Alarm and its mountin...

Страница 9: ...ith a damp cloth and dry thoroughly WARNING Do not paint your Alarm Other than the maintenance and stop sounding shortly after the button is released Repeat this procedure for all other Alarms in the...

Страница 10: ...e chamber base 8 Fit a new chamber top and clip in place by turning clock wise 15 degrees 9 Insert the thermistor PCB into the sockets and ensure the thermistor is perpendicular to the chamber see fig...

Страница 11: ...s check the replace by date marked on the side of the unit Before the Alarm is safely discarded remove from the mounting plate disconnect the batteries Do not put the Alarm into a fire The Alarm shoul...

Страница 12: ...any interference including interference that may cause undesired operation of the device Le pr sent appareil est conforme aux cnr d Industrie Canada applicables aux appareils radio exempts de licence...

Отзывы: