Pro Tip

Pressing the test button

 on the smoke alarm will beep both the panel 

and smoke alarm.

Specifications

Physical 

Housing Dimensions
Weight with Batteries
Mounting Fastener

4.7 x 1.8 inches (12.0 x 4.6 centimeters)
7.36 ounces (210 grams)
#6 screws and anchors (provided)

Environmental

Operating Temperature
Maximum Humidity

40°F to 100°F  (4.4°C to 37.8°C), Long Term
15% to 95% non-condensing relative humidity

Sensor Specifications

Frequency
Replacement Batteries
Transmitted Indications
Loudness
Smoke Sensitivity
Heat Sensor

319.5 MHz
Two Panasonic® CR123A   
Low Battery, Supervision
85 dBA at 10 feet (3m) minimum
1.95% to 4% OBS/Foot
135 ± 5°F (57 ± 2°C)

Certification

RE114

FCC, IC, UL217, ULC531

Specifications subject to change without notice.

47-0023-01 • RevC • 2019-02-11

 Tech Support Line • (888) 88-ALULA • (888) 882-5852

alula.net

WARRANTY

Alula will replace non-portable products that are 

defective in their first five (5) years and all defective 

portable products in their first two (2) years.

IC NOTICE

This device complies with Industry Canada license-

exempt RSS standard(s). Operation is subject to the 

following two conditions:
(1) This device may not cause interference, and

(2) This device must accept any interference, including 

interference that may cause undesired operation of 

the device.

Le présent appareil est conforme aux cnr d’Industrie 

Canada applicables aux appareils radio exempts de 

licence. L’exploitation est autorisée aux deux conditions 

suivantes:
(1) L’appareil ne doit pas produire de brouillage, et

(2) L’utilisateur de l’appareil doit accepter tout 

brouillage radioélectrique subi, même si le 

brouillage est susceptible d’en compromettre le 

fonctionnement.

IC: 8310A-RE114

FCC NOTICE

This device complies with Part 15 of the FCC rules. 

Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.

(2) This device must accept any interference that may 

be received, including interference that may cause 

undesired operation.

Changes or modifications not expressly approved by 

Alula could void the user’s authority to operate this 

equipment.
FCC ID: U5X-RE114

TRADEMARKS

Alula is a trademark owned by Alula Holdings, LLC.

“Interlogix” is a trademark owned by United 

Technologies Electronic Controls Inc.
Alula products will function with Interlogix systems.  

However, no Alula product is produced by, endorsed 

by, or is officially associated with Interlogix. 

Alula recommends verifying proper enrollment and 

operation, per control panel installation instructions, at 

installation.
Panasonic is a registered trademark owned by 

Panasonic Corporation.

Содержание RE114

Страница 1: ...isted onto the smoke alarm 4 Remove the mounting plate and refer to Sections 2 and 6 for positioning and installation 5 After mounting plate is installed restore the smoke alarm onto the mounting plat...

Страница 2: ...s every 48 sec 2 Beeps End of Life Off 3 Flashes every 48 sec 3 Beeps Silence Sounding Alarm Press Release Button 1 Flash every 8 sec Off Off for 10 mins Silence End of Life indication up to 30 days P...

Страница 3: ...every level of a dwelling unit including basements 4 On every level of a residential board and care occupancy small facility including basements and excluding crawl spaces and unfinished attics 5 In t...

Страница 4: ...Smoke Alarms must be mounted away from corners Keep at least 305mm 12 from walls and corners see Figure 3 Additionally mount the unit at least 305mm 12 from any light fitting or decorative object whic...

Страница 5: ...ry replacement Locate the Alarm at least 1m 39 from dimmer controlled lights and wiring as some dimmers can cause interference Locate Alarm at least 1 5m 59 and route wiring at least 1m away from fluo...

Страница 6: ...press the test hush button Do not attempt to recharge or burn the battery as it may explode If it is necessary to remove the battery for separate disposal handle carefully to avoid possible eye damag...

Страница 7: ...the alarm sound or to those who may be incapable of safely evacuating the area unassisted Limitations of Heat Alarms There are various situations where a Heat Alarm may not be effective Fires where th...

Страница 8: ...essary it is possible to further secure the Alarm by using a No 2 or No 4 2 to 3mm 1 8 diameter not supplied self tapping screw 6 to 8mm 1 4 long see Figure 7d to firmly lock the Alarm and its mountin...

Страница 9: ...ith a damp cloth and dry thoroughly WARNING Do not paint your Alarm Other than the maintenance and stop sounding shortly after the button is released Repeat this procedure for all other Alarms in the...

Страница 10: ...e chamber base 8 Fit a new chamber top and clip in place by turning clock wise 15 degrees 9 Insert the thermistor PCB into the sockets and ensure the thermistor is perpendicular to the chamber see fig...

Страница 11: ...s check the replace by date marked on the side of the unit Before the Alarm is safely discarded remove from the mounting plate disconnect the batteries Do not put the Alarm into a fire The Alarm shoul...

Страница 12: ...any interference including interference that may cause undesired operation of the device Le pr sent appareil est conforme aux cnr d Industrie Canada applicables aux appareils radio exempts de licence...

Отзывы: