Clear Login Information
If you are unable to perform an Administrator login (because the Username and
Password information has become corrupted, or you have forgotten it, for exam-
ple), you can clear the login information with the following procedure:
1. Power off the switch and remove the top cover of the Switch module case.
2. Short the jumper labeled Restore Default Password.
3. Power on the switch.
The following message appears on the LCD display:
USERNAME AND PASSWORD INFORMATION HAS BEEN CLEARED.
PLEASE POWER OFF THE SWITCH, REMOVE THE JUMPER, CLOSE
THE CASE, THEN RESTART.
4. After you restart, the OSD login function acts the same way it did the first
time the switch was run (see p. 23), and you can reset passwords for the
Administrator and Users.
Warning! Performing any of the procedures described under Clear
Login Information, Removing the KVM Module, and Removing the
Keyboard and Touchpad improperly could void your warranty.
Continue at your own risk. If you are uncertain as to what to do,
please contact ALTUSEN service support.