- 4 -
WayPoint30A Series Installation Guide
Bottom of Enclosure
Suggested
Locations
for Wiring Inlets
Fig. 1
LED Identification Chart:
ON
OFF
Normal operating condition.
No AC output. Blown fuse or tripped PTC, illuminated master power disconnect
circuit breaker is tripped or OFF, AC failure.
To reset a tripped PTC turn the power off for 1 minute and then turn it back on.
Technical Specifications:
Parameter
Description
Input power requirements
115VAC, 60Hz, 3A or 230VAC, 50Hz, 1.5A.
Indicators
Individual power output LED indicators.
Illuminated master power switch.
Environmental Conditions
Operating Ambient Temperature:
For 24VAC @ 12.5A output: - 40°C to 60°C (- 40°F to 140ºF).
For 28VAC @ 10.0A output: - 40°C to 70°C (- 40°F to 158ºF).
Relative Humidity:
85%, +/- 5%
Storage Temperature:
- 40ºC to 75ºC (- 40ºF to 167ºF).
Operating Altitude:
- 304.8 to 2,000m.
Regulatory Compliance
UL/cUL Listed for
Information Technology Equipment (UL 60950-1)
Equipment to be Installed Outdoors (UL 60950-22).
CE
European Conformity.
For fuse protected models:
Replace blade type fuses with ratings from 3A up to 10A.
WayPoint30AU and WayPoint30A4U incorporates 10A fuses. WayPoint30A8U incorporates 5A fuses.