VertiLine563V

Overview:

Altronix Vertiline563V is a EIA 19” 1U rack mountable dual independent power supply with optional battery 
backup that provides 56VDC. It is intended primarily to be used in conjunction with respective Altronix current 
and future products that require 56VDC input such as: eBridge4PCRX, eBridge16PCRX and eBridge1PCRX 
multi-port and single port IP/PoE over coax adapters. However, it can also be employed wherever 56VDC level 
power sources are needed.
There are applications which may require delivering power in a range of 48VDC to 57VDC over CAT5 cable 
for distances up to 100m. For these applications transmission at the higher voltage is more efficient, as it reduces 
cable losses when compared to the lower voltage.

Specifica tions:

Agency Listings:

• 

CE  

European Conformity.

• 

C-Tick  

C-Tick Compliant.

Input:

•  Input 220VAC, 50/60Hz, 3A.

Output:

•  56VDC @ 3A each output.
 (When using battery backup, output rating is 
  56V/2.7A for respective outputs).

Battery Backup:

•  Built-in charger for sealed lead acid or 
  gel type batteries.*
 

*External batteries are optional.

•  Automatic switch over to stand-by battery 
  when AC fails.
•  Maximum charge current 0.3A.

Additional Features:

•  Two (2) AC LED indicators.
•  IEC 320 - 3-wire grounded line cord (detachable).
•  Unit can be rack or shelf mounted.

Rack Dimensions 

(H x W x D approx.)

•  1U rack mount chassis for use in standard 
  EIA 19” rack.
  1.625” x 19.125” x 8.5” 
  (41.3mm x 486mm x 216mm)

Accessories:

  RE2 - Rack Mount Battery Enclosure:

•  Fits up to four (4) 12VDC/7AH batteries.
•  2U rack mount chassis for use in standard 
  EIA 19” rack.

Installation Instructions:

1. Suitable for rack, wall or shelf mounting (refer to page 4).
  a.  If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack 
    environment may be greater than room ambient. Therefore, consideration should be given to installing 
    the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by 
  the 

manufacturer.

  b. Installation of the equipment in a rack should be such that the amount of airflow required for safe 
    operation of the equipment is not compromised.
  c.  Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to 
    uneven mechanical loading.
  d. Consideration should be given to the connection of the equipment to the supply circuit and the effect that
    overloading of the circuits might have on overcurrent protection and supply wiring. 
    Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
  e.  Reliable earthing of rack-mounted equipment should be maintained.
    Particular attention should be given to supply connections other than direct connections to the branch 
    circuit (e.g. use of power strips). 
2. Insert terminal blocks included with unit in sockets in the rear of unit (Fig. 2, pg. 4).
3.  Plug power cord into grounded 220VAC, 50/60Hz receptacle to energize unit (Fig. 2a, pg. 4).
4.  Measure output voltage on both output terminal blocks marked [– OUT1] + and [– OUT2 +] before connecting 
  devices. Output voltage should be nominally 56VDC.
5. Unplug power cord from grounded 220VAC, 50/60Hz receptacle to de-energize unit 
  (Fig. 2a, pg. 4).
6. 

Typical 56VDC device hookup:

  Connect either one (1) or two (2) devices to VertiLine563V.
    Connect first 56VDC device Input to VertiLine563V terminals 
    marked [– OUT1 +].
    If applicable, connect second 56VDC device Input to VertiLine563V 
    terminals marked [– OUT2 +] 
  (Fig. 1, pg. 2, Fig. 3, pg. 4), carefully observing polarity.
  

CAUTION: Outputs 1 and 2 should not be connected in parallel.

56VDC

output

To optional

stand-by

batteries

Fig. 1

Содержание VertiLine563V

Страница 1: ...Rev 041414 More than just power TM VertiLine563V Rack Mount Power Supply Charger Installation Guide Z1409 ...

Страница 2: ...ack assembly the operating ambient temperature of the rack environment may be greater than room ambient Therefore consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature Tma specified by the manufacturer b Installation of the equipment in a rack should be such that the amount of airflow required for safe operation of the equipment...

Страница 3: ...Bridge16PCRX Input 2 to VertiLine563V terminals marked OUT2 Fig 1 pg 2 Fig 5 pg 6 carefully observing polarity 8 When batteries are not used a loss of AC will result in the loss of output voltage When the use of stand by batteries is desired they must be lead acid or gel type Connect four 4 12VDC batteries wired in series to terminals marked BAT Fig 1 pg 2 carefully observing polarity 9 Plug power...

Страница 4: ...tachable 2b 56VDC 3A per output 2c Stand by battery connections Maximum charge current 0 3A 2a 2c 2b Fig 3 VertiLine563V configured with two 2 56VDC devices and four 4 12VDC stand by batteries 56VDC Device Altronix VertiLine563V rear Four 4 12VDC batteries optional Input 56VDC Device Input ...

Страница 5: ...ine563V configured with two 2 eBridge4PCRX and four 4 12VDC stand by batteries wired in series optional Altronix eBridge4PCRX rear Altronix eBridge4PCRX rear Altronix VertiLine563V rear Four 4 12VDC batteries optional Input Input ...

Страница 6: ...d RE2 Rack Battery Enclosure optional Data In Data In Altronix eBridge16PCRX rear Altronix VertiLine563V rear Altronix RE2 rear with four 4 12VDC 7AH batteries Altronix model BT126 Data In Data In 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Input 1 Input 2 BAT4 BAT3 BAT2 BAT1 ...

Страница 7: ...ts A on the left and right side of rack chassis using four 4 flat head screws B included Fig 7a 2 Place unit at desired location and secure with mounting screws not included Fig 7b Caution It is necessary to make sure mounting screws are securely fastened to a beam when installing the unit vertically Fig 7b Fig 7 Fig 7a Shelf Installation 1 Position and affix rubber pads C included at each corner ...

Страница 8: ...8 567 8181 fax 718 567 9056 website www altronix com e mail info altronix com Lifetime Warranty Made in U S A IIVertiLine563V G24R MEMBER Rack Mechanical Drawing and Dimensions H x W x D approx 1 625 x 19 125 x 8 5 41 3mm x 485 8mm x 216mm Fig 9 8 5 216mm 0 75 19 05mm TOP BOTTOM 19 125 486mm 17 625 448mm 1 625 41 3mm 8 5 216mm ...

Отзывы: