VertiLine563V
- 3 -
The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the
user to the presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that
may be of sufficient magnitude to constitute an electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of
important operating and maintenance (servicing) instructions in the literature accompanying
the appliance.
CAUTION: To reduce the risk of electric shock do not open enclosure.
There are no user serviceable parts inside.
Refer servicing to qualified service personnel.
7.
For application hookup to Altronix eBridge IP/PoE over coax products:
a. eBridge4PCRX - Connect either one (1) or two (2) eBridge4PCRX to VertiLine563V.
Connect first eBridge4PCRX Input to VertiLine563V terminals marked [– OUT1 +].
If applicable, connect the second eBridge4PCRX Input to VertiLine563V terminals marked [– OUT2 +]
(Fig. 1, pg. 2, Fig. 4, pg. 5), carefully observing polarity.
b. eBridge16PCRX - Connect eBridge16PCRX Input 1 to VertiLine563V terminals marked [– OUT1 +],
connect eBridge16PCRX Input 2 to VertiLine563V terminals marked [– OUT2 +]
(Fig. 1, pg. 2, Fig. 5, pg. 6), carefully observing polarity.
8. When batteries are not used, a loss of AC will result in the loss of output voltage. When the use of stand-by
batteries is desired, they must be lead acid or gel type. Connect four (4) 12VDC batteries wired in series to
terminals marked [+ BAT –] (Fig. 1, pg. 2), carefully observing polarity.
9. Plug power cord into grounded 220VAC, 50/60Hz receptacle to energize unit (Fig. 2a, pg. 4).
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to
rain or moisture. This installation should be made by qualified service personnel and
should conform to the National Electrical Code and all local codes.
Technical Specifications:
Parameter
Description
No. of Outputs
Two (2) outputs. Each output rated @ 150W each. Current per output = 2.7A.
Input Power
Requirements
220VAC, 50/60Hz, 3A
Indicators
AC LEDs, one (1) per power supply.
Battery Backup
Battery stack is 4x 12VDC lead acid gel cells connected in series.
Battery backup one (1) per power supply.
Environmental
Conditions
Operating ambient temperature: 0ºC to 40ºC (32ºF to 104ºF).
Relative humidity: 85%, +/– 5%
Storage temperature: – 20º to 70ºC (– 4º to 158ºF).
Operating altitude: –304.8 to 3,048m.
Regulatory
Compliance
CE European Conformity,
C-Tick compliant.
Z1409