6.  Select 24VAC or 28VAC power output for cameras 1-16 with the corresponding voltage adjustment switches
 

(Fig. 1b, pg. 4).

7.  Measure output voltage before connecting cameras. This helps avoiding potential damage.
 

All terminals with common suffix (P) “1P, 2P ...” are the same polarity.

8.  Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 3, pg. 6)
9.  Connect the power outputs of terminals marked [1P & 1N] to the power inputs of camera 1 (Fig. 2, pg. 5).
 

Repeat this step for each additional camera (Outputs 2-16). After wiring is completed insert terminal block into the 

 

corresponding connector and secure by tightening the screws.

10.  Upon completion of wiring, set illuminated master power disconnect circuit breaker to the 
 

ON (RESET) position (Fig. 3, pg. 6).

11.  The power LEDs (Green) on the faceplate for Outputs 1-16 will illuminate when AC power is present
 

(Fig. 1a, pg. 4). If any of these LEDs are off, a loss of AC power output may be due to a blown fuse or a tripped  

 

 

PTC caused by a short circuit or overload condition. If all of the LEDs are OFF there may be a complete loss of 

 

supply power to the Vertiline unit or the illuminated master power disconnect circuit breaker is in the OFF position

 

or the main fuse 1-8 or 9-16 is blown (Fig. 1d, pg. 4).* 

 

To restore the power output for Vertiline16 or Vertiline166:

 

 

1- Switch corresponding output voltage switch to the OFF position (Fig. 1b, pg. 4).

 

 

2- Eliminate the trouble condition.

 

 

3- Replace the corresponding automotive blade fuse.*

 

 

4- Switch output voltage switch to the 24VAC or 28VAC position as desired (Fig. 1b, pg. 4).

 

To restore the power output for Vertiline16D or Vertiline166D:

 

 

1- Switch corresponding output voltage switch to the OFF position (Fig. 1b, pg. 4).

 

 

2- Eliminate the trouble condition.

 

 

3- Allow 1 minute for PTC to cool off.

 

 

4- Switch output voltage switch to the 24VAC or 28VAC position as desired (Fig. 1b, pg. 4).

*Note: Replace fuses with same type and rating:
 

 

Output fuses are rated @ 3A for all models.

 

 

Main fuse ratings:

 

 

10A for Vertiline16 and Vertiline16D.

 

 

15A for Vertiline166 and Vertiline166D.

Automotive
Blade Fuse

Содержание Vertiline16

Страница 1: ...tiline16D 24VAC or 28VAC 10A 24VAC or 28VAC 10A Sixteen 16 fuse protected outputs Sixteen 16 PTC protected outputs Vertiline166 Vertiline166D 24VAC or 28VAC 14A 24VAC or 28VAC 14A Sixteen 16 fuse protected outputs Sixteen 16 PTC protected outputs More than just power TM Rev 031808 ...

Страница 2: ...ode and all local codes Installation Instructions 1 Set the input voltage selector switch located on the left side of the Vertiline unit facing front panel for 115VAC or 230VAC operation Fig 1c pg 4 2 Attach mounting brackets to Vertiline unit for rack or wall mount installation Figs 4 5 pg 7 Affix rubber pads to Vertiline for shelf installation Fig 6 pg 7 3 Secure the unit in a rack mount unit to...

Страница 3: ...tput may be due to a blown fuse or a tripped PTC caused by a short circuit or overload condition If all of the LEDs are OFF there may be a complete loss of supply power to the Vertiline unit or the illuminated master power disconnect circuit breaker is in the OFF position or the main fuse 1 8 or 9 16 is blown Fig 1d pg 4 To restore the power output for Vertiline16 or Vertiline166 1 Switch correspo...

Страница 4: ...t 1d Main Fuse Protects the transformer against overload 1a LED s 1 16 Power LED indicators Fig 1 1c Input Voltage Switch Selects 115VAC 230VAC 50 60Hz switch is located on the left side of the unit 115VAC 220VAC 1e Power Outputs 24VAC or 28VAC 1f Output Fuses Automotive blade fuses Vertiline16 Vertiline16D Vertiline166 or Vertiline166D front Vertiline16 or Vertiline166 rear Vertiline16D or Vertil...

Страница 5: ...FF 24VAC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 28VAC OFF 24VAC OFF RESET AC POWER 13 14 15 16 N P N P N P N P 9 10 11 12 N P N P N P N P Main Fuse 9 16 5 6 7 8 N P N P N P N P 1 2 3 4 N P N P N P N P Main Fuse 1 8 Typical Hookup ...

Страница 6: ...wered Circuit breaker tripped Switch not illuminated Power LEDs on faceplate are not illuminated Outputs not powered To reset circuit breaker set power switch to the ON RESET position Fig 3 pg 6 The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product s enclosure that may be of suffi...

Страница 7: ...s of rack chassis Fig 4a 2 Install mounting brackets A on the left and right side of rack chassis using the two 2 flat head screws B included Fig 4b 3 Place unit into desired EIA 19 rack position and secure with mounting screws not included Fig 4c Fig 6 Fig 5 Shelf Installation 1 Position and affix rubber pads C included at each corner on the bottom of the unit Fig 6 2 Place unit in desired locati...

Страница 8: ...esponsible for any typographical errors 140 58th Street Brooklyn New York 11220 USA 718 567 8181 fax 718 567 9056 web site www altronix com e mail info altronix com Lifetime Warranty Made in U S A IIVertiline16Series F10P Notes MEMBER ...

Отзывы: