Vertiline16
Overview:
Altronix Vertiline CCTV Rack Mount Power Supplies provide 16 power outputs in a space saving 1U EIA 19” rack mount
chassis which may be rack, wall or shelf mounted. The units feature individually selectable 24VAC and/or 28VAC power
outputs with surge suppression. Vertiline CCTV Rack Mount Power Supplies are also available in eight (8) and twenty-four
(24) output models with various power ratings.
Specifications:
Sixteen (16) Output Rack Mount Configuration Reference Chart:
Altronix
Model
Number
Output Voltage (VAC)
Total Output Current (Power)
Number of Outputs
Output Protection
Class 2 Rated Power- Limited Output Protection
Current (max. per output)
Fuse Rating
Main Fuse Rating
115VAC 60Hz Input Current
230VAC 50/60Hz Input Current
Agency Listings
UL Listings and File Numbers
Vertiline16
24VAC or
28VAC
10A
16 Fused
--
3A
3A
10A
3A
1.6A
UL Listed for
Commercial
CCTV
Equipment
(UL 2044).
Vertiline16D
24VAC or
28VAC
10A
16
--
PTC
2.5A
--
Vertiline166
24VAC or
28VAC
14A
16 Fused
--
3A
3A
15A
4A
2.5A
Vertiline166D 24VAC or
28VAC
14A
16
--
PTC
2.5A
--
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. This
installation should be made by qualified service personnel and should conform to the National Electrical
Code and all local codes.
Installation Instructions:
1. Set the input voltage selector switch located on the left side of the Vertiline unit (facing front panel) for
115VAC or 230VAC operation (Fig. 1c, pg. 4).
2. Attach mounting brackets to Vertiline unit for rack or wall mount installation (Figs. 4-5, pg. 7). Affix rubber pads to
Vertiline for shelf installation (Fig. 6, pg. 7).
3. Secure the unit in a rack, mount unit to a wall or place unit on a shelf as desired (unit should be spaced at least 3”
from any video monitors). When installing the unit in a rack allow for one half of a U spacing above the unit
for ventilation.
4. Plug the grounded AC line cord (included) into the IEC 320 connector of the Vertiline unit (Fig. 1g, pg. 4).
Insert the plug end of the line cord into a grounded AC receptacle.
5. Set illuminated master power disconnect circuit breaker to the (ON) position (Fig. 3, pg. 6).
Input:
• Selectable 115VAC 60 Hz or 240VAC 50/60 Hz input.
Output:
• Sixteen (16) individually selectable 24VAC or 28VAC
power outputs with OFF position.
• External blade fuses or PTC protected outputs.
• Surge suppression.
Features:
• Sixteen (16) power LED indicators.
• Illuminated master power disconnect circuit breaker
with manual reset.
• IEC 320 - 3-wire grounded line cord (detachable).
• Removable terminal blocks with locking screw flange.
Mechanical:
• Units can be rack, wall or shelf mounted.
• Modular 1U standard EIA 19” rack mount chassis
• Enclosure Dimensions (H x W x D approx.):
1.625” x 19.125” x 8.5” (41.3mm x 486mm x 216mm).