- 4 - 

SMP10C24X220 Series

Caution: Equipment to be installed / serviced by authorized / trained personnel only. 
Shut branch circuit power before installing / servicing equipment.

WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. 
This installation should be made by qualified service personnel and should conform to the National 
Electrical Code and all local codes.

The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user 
to the presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may 
be of sufficient magnitude to constitute an electric shock.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of 
important operating and maintenance (servicing) instructions in the literature accompanying the 
appliance.

CAUTION: To reduce the risk of electric shock do not open 
enclosure. There are no user serviceable parts inside. 
Refer servicing to qualified service personnel.

LOW BAT

NC    C   NO     NC   C     NO

AC FAIL

--- 

 BAT  

+-

-- 

 DC  

+

LG

N

5A 250V

OFF    ON

AC

DC

Power Supply

Board

220VAC 

power mains

Ground

Lug

Power

Distribution

Module(s)

Optional Rechargeable

12VDC Stand-by Battery

Optional Rechargeable

12VDC Stand-by Battery

LOW BAT

NC    C   NO     NC   C     NO

AC FAIL

--- 

 BAT  

+-

-- 

 DC  

+

LG

N

5A 250V

OFF    ON

AC

DC

Power Supply

Board

220VAC 

power mains

Ground

Lug

Power

Distribution

Module(s)

Optional Rechargeable

12VDC Stand-by Battery

Optional Rechargeable

12VDC Stand-by Battery

LOW BAT

NC    C   NO     NC   C     NO

AC FAIL

---  BAT  +

---  DC  +

L

G

N

5A 250V

OFF    ON

AC

DC

Power Supply

Board

220VAC 

power mains

Ground

Lug

Power

Distribution

Module(s)

Optional Rechargeable 12VDC Stand-by Battery

Optional Rechargeable 12VDC Stand-by Battery

Fig. 1

Fig. 1a
Switch disables power mains line voltage input.
If stand-by battery (batteries) are connected, the DC output remains on

Fig. 1b

See
LED Diagnostics, 
pg. 3

Содержание SMP10C24X220 Series

Страница 1: ...X220 SMP10PMC24X220 Single Output SMP10PM24P4220 Four 4 Fuse Protected Outputs SMP10PM24P8220 Eight 8 Fuse Protected Outputs SMP10PM24P16220 Sixteen 16 Fuse Protected Outputs SMP10PM24P4CB220 Four 4 P...

Страница 2: ...x 122 BTU Hr System AC input VA requirement 310 5VA Mechanical Enclosure Dimensions H x W x D approx 13 5 x 13 x 3 25 342 9mm x 330 2mm x 82 6mm Accommodates up to two 2 12VDC 7AH batteries Installati...

Страница 3: ...dels only 9 Connect appropriate signaling notification devices to AC Fail and Low Bat supervisory relay outputs marked NC C NO Fig 1b pg 4 or Fig 2b pg 5 10 Slide Power ON OFF switch to ON position LE...

Страница 4: ...to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance CAUTION To reduce the risk of electric shock do not open enclosure There are...

Страница 5: ...able 12VDC Stand by Battery Optional Rechargeable 12VDC Stand by Battery L 5A 250V OFF ON LOW BAT NC C NO NC C NO AC FAIL BAT DC AC DC Board 115VAC power mains Di Optio 12VD Optional Rechargeable 12VD...

Страница 6: ...UTS P FUSED POWER OUTPUTS 1 2 3 4 5 6 7 8 D1 INPUT R1 LED DC Output to devices From Power Supply Board Factory Installed ON OFF SW1 Used on PTC Models Power Distribution Module s common outputs protec...

Страница 7: ...SMP10C24X220 Series 7 Notes...

Страница 8: ...s BC300 13 5 x 13 x 3 25 342 9mm x 330 2mm x 82 6mm Enclosure accommodates up to two 2 12VDC 7AH batteries Also available to accommodate up to two 2 12VDC 12AH batteries please contact Altronix 1 40 3...

Отзывы: