Overview:

These Altronix Rack Mount CCTV Power Supplies provide 24VAC or 28VAC distributed via thirty-two (32) fuse or PTC
protected outputs for powering CCTV Cameras, heaters and other video accessories.

Thirty-two (32) Output Rack Mount Configuration Reference Chart:

R2432300UL

24

12.5 amp (300VA) 

32

-

x

3.5 amp

3 amp

28

10 amp (280VA)

32

-

x

3.5 amp

3 amp

R2432300ULCB

24

12.5 amp (300VA)

32

x

-

2.5 amp

3 amp

28

10 amp (280VA)

32

x

-

2.5 amp

3 amp

R2432600UL*

24

25 amp (600VA) 

32

-

x

3.5 amp

6 amp

28

20 amp (560VA)

32

-

x

3.5 amp

6 amp

R2432600ULCB*

24 

25 amp (600VA) 

32

x

-

2.5 amp

6 amp

28

20 amp (560VA)

32

x

-

2.5 amp

6 amp

*24VAC models: Outputs 1-16 provide 12.5 amp (300VA) max. Outputs 17-32 provide 12.5 amp (300VA) max.
*28VAC models: Outputs 1-16 provide 10 amp (280VA) max. Outputs 17-32 provide 10 amp (280VA) max.

Specifications:

• UL Listed for Commercial CCTV Equipment (UL2044).

• Surge suppression.

CUL Listed - CSA Standard C22.2 No.1-98, Audio,

• Unit maintains camera synchronization.

Video and Similar Equipment.

• Ease of installation saves time and eliminates

• 2U rack mount chassis for use in standard EIA 19” rack.

costly labor.

• Removable terminal blocks with locking screw flange.

Rack Dimensions:

• Power switch with built-in circuit breaker.

3.25”H x 19.125”W x 8.5”D

• Thirty-two (32) individual power LED indicators.

Installation Instructions:

1. The unit is factory set for 24VAC operation.  

For 28VAC operation, adjust unit prior to mounting and applying power as follows: 

a. Open bottom of unit by removing six (6) screws (Rack Mechanical Drawing & Dimensions, pg. 4).
b. Change the wire position so that the black wire [28V] is connected to the terminal marked [P] and 

the yellow wire [24V] is connected to the terminal marked [S] (Fig. 1D, pg. 3).

c. After securing all wires for proper voltage place bottom panel back on the unit and fasten with the six (6) screws.

2. Mount unit in desired rack location (Space unit at least 3” from any video monitors), Do not obstruct side air vents.
3. Set power switch on back of unit to the OFF position (Fig. 1C, pg. 3).
4. Plug power cord into grounded 115VAC 50/60 Hz receptacle (Fig. 1B, pg. 3), ground should be connected 

as indicated in (Fig. 1E, pg. 3).

5. Set power switch on back of unit to the ON (RESET) position and measure output voltage before

connecting devices (Fig. 1C, pg. 3). This helps avoid potential damage. All terminals with common
suffix (P) “1P, 2P...” are the same polarity.

6. Set power switch on back of unit to the OFF position (Fig. 1C, pg. 3).
7. Connect devices to removable terminal blocks marked [1P & 1N through 8P & 8N] (Fig. 1A, pg. 3)

When wiring is completed on terminal blocks they can be locked down by tightening screw flanges.

8. Upon completion of wiring, set power switch on back of unit to the ON (RESET) position (Fig. 1C, pg. 3).
9. Green power LEDs on faceplate will illuminate when AC power is present. When an output is in a trouble condition 

(blown fuse or tripped PTC) the corresponding LED will not be illuminated (Fig. 1, pg. 3).
a. Blown fuse (R2432300UL & R2432600UL) - Set power switch on back of unit to the 

OFF position (Fig. 1C, pg. 3). Remove front faceplate to access fuses. 

Altronix 
Model Number

Output Cur

rent

(max per output)

Total Output   

Cur

rent (P

ow

er)

Output 

V

oltage

(V

A

C)

115V

A

C 50/60Hz     

Input Cur

rent 

Fuse Protected

Outputs

- 2 -

Number of 

Outputs PTC Protected

Outputs (Class 2

po

w

er limited).