NetWaySP4PX Installation Guide 

- 3 -

Overview:

Altronix NetWaySP4PX Media Converter with Integral Power, provides four (4) 1Gb SFP ports and four (4) ports 

for up to 120W per port (480W total) to be transmitted over single/multi-mode fiber or composite cable (powered) 

cable (fiber + copper combined) to NetWay Spectrum PoE Hardened Switches. 

Features:

Agency Listings:

• 

CE

  

European Conformity.

Input:

•  115VAC, 60Hz, 5.5A or 230VAC, 50/60Hz, 3A

 (auto-ranging).

Power:

•  Four (4) 56VDC non power-limited outputs 

  up to 120W max. full power per port.

  Total power: 480W.

•  IEEE 802.3af, IEEE 802.3at and 

  IEEE 802.3bt compliant.

•  Short circuit protection.

SFP Ports:

•  Four (4) Gigabit SFP/Fiber ports.

•  Use with SFP module 1000Base-X (1Gb), 

  compliant to Class 1 laser product (not included).

Ethernet/Data:

•  Four (4) ports to switch.

•  Wire type: 4-pair CAT5e and higher.

•  Connectivity: RJ45, auto-crossover.

• Speed: 10/100/1000Mbps.

•  Distance: up to 100m.

Environmental:

  Refer to Environmental Conditions on page 6.

Battery Backup:

•  Built-in battery charger 

 

(optional rack mount battery enclosure - RE2)

.

•  Automatic switchover to stand-by battery when 

  AC fails. 

Compatible PoE Hardened Switches 
and Accessories:

NetWaySP1BTWPN:

 

3-port (802.3bt) PoE Hardened 

     

Switch with (1) SFP port.

NetWaySP3WPN:

 

3-port PoE Hardened Switch 

     

with (1) SFP port.

NetWay4EWPN:

 

4-port PoE Hardened Switch 

     

with (1) SFP port.

NetWaySP4WPN:

 

4-port PoE Hardened Switch 

     

with (2) SFP ports.

NetWaySP4BTWPN:

 

4-port (802.3bt) PoE Hardened  

     

Switch with (2) SFP ports.

NetWaySP8WPN:

 

8-port PoE Hardened Switch 

     

with (2) SFP ports.

RE2: 

 

Rack Mount Battery Enclosure 

     

accommodates up to four (4) 

   

12VDC/7AH 

batteries

Installation Instructions:

Wiring methods shall be in accordance with the National Electrical 

Code (ANSI/NFPA70), local codes, and the authorities having 

jurisdiction. NetWaySP4PX is not intended to be connected to 

outside plant leads. These products are for indoor use only and 

must be installed within the protected premises. 

NetWaySP4PX must be installed in a restricted access area. 

If battery bracket is removed, must be installed in a restricted 

access area 

(Fig. 1b, pg. 3)

The outputs are of a non-limited power source.

For non-limited power sources, additional protective circuitry and/or an appropriate fire enclosure for the products 

supplied by this device are required.

1. Attach mounting brackets to the unit for rack or wall mount installation 

(Fig. 4 or 5, pg. 8)

  Affix rubber pads to the unit for shelf installation 

(Fig. 6, pg. 8)

.

2. Secure the unit in a rack or on a wall, or place unit on a shelf as desired.

 

Note:

 The following factors should be taken into consideration when installing these rack mount units:

    a. The unit is to be installed in a space where the maximum ambient temperature does not exceed 

   104ºF 

(40ºC).

    b. Take care to ensure that there is sufficient air flow around the unit and that obstructions do not impede it.

    c.  When mounting units in a rack, take care to avoid uneven loading which can cause a hazardous condition.

3. Plug the grounded AC line cord (included) into the IEC 320 connector of the unit 

(Fig. 2f, pg. 4)

. Plug unit 

  into a reliable earth grounded socket. When using multiple units, the sum of the individual name plate ratings 

  should not exceed the supply circuit rating. 

Do not connect to a receptacle controlled by a switch.

Fig. 1a 

Fig. 1b

Содержание NetWaySP4PX

Страница 1: ...ice Rep Name ___________________________________ Address ______________________________________________ Phone ___________________ Installation Guide NetWaySP4PX 4 port Ethernet to Fiber Media Converte...

Страница 2: ...X Installation Guide Table of Contents Overview pg 3 Features pg 3 Installation Instructions pg 3 Recommended Altronix SFP Modules pg 4 Typical Applications pg 5 Technical Specifications pg 6 Mounting...

Страница 3: ...Enclosure accommodates up to four 4 12VDC 7AH batteries Installation Instructions Wiring methods shall be in accordance with the National Electrical Code ANSI NFPA70 local codes and the authorities ha...

Страница 4: ...ct four 4 12VDC batteries in series to terminals marked BAT Fig 2h pg 4 Note When batteries are not used a loss of AC will result in a loss of output voltage Recommended Altronix SFP Modules Altronix...

Страница 5: ...t Panel WiFi Access Point Copper Fiber Composite Powered Fiber Cable Copper Fiber NetWay Spectrum PoE Hardened Switch IP Camera Device IP Camera Device WiFi Access Point NetWay Spectrum PoE Hardened S...

Страница 6: ...CE European Conformity Weights approx Product 3 8 lbs 1 7kg Shipping 6 0 lbs 2 7kg The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presen...

Страница 7: ...NetWaySP4PX Installation Guide 7 Notes...

Страница 8: ...5a 2 Place unit at desired location and secure with 6 size screws or larger not included Fig 5b Caution It is necessary to make sure mounting screws are securely fastened to a beam when installing the...

Отзывы: