NetWaySP4PX Installation Guide
4. Connect structured cable from ethernet switch/NVR (network video server) to RJ45 jack marked
[Ethernet 1-4]
(Fig. 2e, pg. 4)
.
Note:
All cabling and wire must be UL Listed and/or Recognized wire suitable for their application.
5. Connect Composite (Powered) Fiber cable: fiber portion to port marked [SFP 1-4], copper portion connects
to output marked [OUT 56VDC, 1-4]
(Fig. 2b & 2d, pg. 4)
.
6. Connect opposite end of Composite (Powered) Fiber cable: fiber portion to SFP port on NetWay Spectrum
Hardened Switch, copper portion connects to power input of NetWay Spectrum Hardened Switch,
carefully
observing correct polarity
(Refer to respective NetWay Spectrum Switch Installation Guide).
7. When the use of stand-by batteries is required, they must be sealed lead acid or gel type. Use 14 AWG or
larger for all power connections. Connect four (4) 12VDC batteries in series to terminals marked [+ BAT –]
(Fig. 2h, pg. 4).
Note:
When batteries are not used, a loss of AC will result in a loss of output voltage.
Recommended Altronix SFP Modules:
Altronix P1MM, P1SM10, P1AB2K and P1GCE are hot-pluggable SFP fiber transceiver modules and are readily
usable with all Altronix Spectrum fiber optic equipment for 1Gb transmission rates.
P1MM - For use with Multi-Mode Fiber for distances up to 550m.
P1SM10 - For use with Single-Mode Fiber for distances up to 10km.
P1AB2K - For use with Single Strand Single-Mode Fiber for distances up to 2km.
P1GCE - For use with CAT5e or better for distances up to 100m.
Fig. 2
2a
LED indicates AC Power is present.
2b
1Gb SFP port.
2c
LED indicates fiber link.
2d
120W max output (480W total power)
2e RJ45 connects to switch
2f
IEC 320 Connector: 115/230VAC (grounded line cord included).
2g
Built-in battery charger: Charges stand-by batteries for applications requiring back-up.
(Optional rack mount battery enclosure available - RE2)
Rear Panel
Front Panel
2b
2d
2a
2c
2e
2f
2g