Maximal3V / Maximal5V / Maximal7V Access Power Controllers (Fused) 

- 9 -

Fig. 4 - 

Maximal7V

+  DC   -

-- 

---  

 BA

T   

+

DC

AC

5A

 25

0V

15

AC DELAY

15

A

 3

2V

 

BAT FAIL

NC   C   NO    NC   C   NO

 

AC FAIL

Power Supply Board

L      G     N

Line

Neutral

Input

220VAC

50/60Hz

Tamper Switch

**24VDC operation: Connect two (2) 12VDC batteries in series

Optional

12VDC Battery**

Optional

12VDC Battery**

Ground Lug

NC 

NO 

CO

M

 

OUTPUT 

1

LED1

F1

NC 

NO 

CO

M

 

OUTPUT 

2

IN  GND

1

IN  GND

2

IN  GND

3

IN  GND

4

IN  GND

5

IN  GND

6

IN  GND

7

MAIN

IN  GND

8

LED2

LED3

LED4

LED5

LED6

LED7

LED8

J2

TR

G

NC 

NO 

CO

M

 

OUTPUT 

3

NC 

NO 

CO

M

 

OUTPUT 

4

NC 

NO 

CO

M

 

OUTPUT 

5

NC 

NO 

CO

M

 

OUTPUT 

6

NO    C     NC

+ INP ---

     T    +  RET  

-

NC 

NO 

CO

M

 

OUTPUT 

7

NC 

NO 

CO

M

 

OUTPUT 

8

- --     

+

Power

- --      

+

Control

F2

F3

F6

F7

F8

F4

F5

J1

J3

FACP                   INTERF

ACE

10A 250V

1  2  3  

4

ON

1  2  3  

4

ON

NC 

NO 

COM

 

OUTPUT 

1

LED1

F1

NC 

NO 

CO

M

 

OUTPUT 

2

IN  GND

1

IN  GND

2

IN  GND

3

IN  GND

4

IN  GND

5

IN  GND

6

IN  GND

7

MAIN

IN  GND

8

LED2

LED3

LED4

LED5

LED6

LED7

LED8

J2

TR

G

NC 

NO 

CO

M

 

OUTPUT 

3

NC 

NO 

CO

M

 

OUTPUT 

4

NC 

NO 

CO

M

 

OUTPUT 

5

NC 

NO 

CO

M

 

OUTPUT 

6

NO    C     NC

+ INP ---

     T    +  RET  

-

NC 

NO 

CO

M

 

OUTPUT 

7

NC 

NO 

CO

M

 

OUTPUT 

8

- --     

+

Power

- --      

+

Control

F2

F3

F6

F7

F8

F4

F5

J1

J3

FACP                   INTERF

ACE

10A 250V

1  2  3  

4

ON

1  2  3  

4

ON

Fig. 4a

Edge of

Enclosure

to Access Control Panel

or U.L. Listed

Reporting Device

Enclosure

Honeywell

Model 112

Tamper Switch

or equivalent

(Not Included)

Содержание Maximal3V

Страница 1: ...M Access Power Controllers Installation Guide Models Include Maximal3V 12VDC 5A or 24VDC 5 4A Sixteen 16 fuse protected outputs Maximal5V 12VDC 9A Sixteen 16 fuse protected outputs Maximal7V 24VDC 9 4...

Страница 2: ...wer Controller Terminal Identification pg 6 Power Supply Board Stand by Battery Specifications pg 6 Power Supply Board Output Voltage Settings pg 7 Access Power Controller Typical Application Diagram...

Страница 3: ...ated 5A 28VDC or VAC d Any combination of the above Sixteen 16 Access Control System trigger inputs Input trigger options a Sixteen 16 normally open NO dry trigger inputs b Sixteen 16 open collector i...

Страница 4: ...oper or high voltage will damage these devices 5 Output options Fig 2 pg 7 The unit will provide either sixteen 16 switched power outputs sixteen 16 dry form C outputs or any combination of both switc...

Страница 5: ...acing a short between terminals marked T and INP will trigger the Fire Alarm Disconnect Remove the short to reset Normally Closed Input Removing the wire from terminal marked INP will trigger the Fire...

Страница 6: ...Fig 4 pg 9 Access Power Controller Terminal Identification Terminal Legend Function Description Power 12VDC or 24VDC input from power supply board Control Not applicable TRIGGER INPUT 1 INPUT 8 IN GN...

Страница 7: ...his application corresponding fuse F8 must be removed Keypad NC C NO COM OUTPUT 1 LED1 F1 NC C NO COM OUTPUT 2 IN GND 1 IN GND 2 IN GND 3 IN GND 4 IN GND 5 IN GND 6 IN GND 7 MAIN IN GND 8 LED2 LED3 LE...

Страница 8: ...3 IN GND 4 IN GND 5 IN GND 6 IN GND 7 MAIN IN GND 8 LED2 LED3 LED4 LED5 LED6 LED7 LED8 J2 TRG NC C NO COM OUTPUT 3 NC C NO COM OUTPUT 4 NC C NO COM OUTPUT 5 NC C NO COM OUTPUT 6 NO C NC INP T RET NC...

Страница 9: ...4 NC C NO COM OUTPUT 5 NC C NO COM OUTPUT 6 NO C NC INP T RET NC C NO COM OUTPUT 7 NC C NO COM OUTPUT 8 Power Control F2 F3 F6 F7 F8 F4 F5 J1 J3 FACP INTERFACE 10A 250V 1 2 3 4 O N 1 2 3 4 O N NC C N...

Страница 10: ...require different conduit knockouts to be used Any conduit knockouts may be used For power limited applications use of conduit is optional All field wiring connections must be made employing suitable...

Страница 11: ...require different conduit knockouts to be used Any conduit knockouts may be used For power limited applications use of conduit is optional All field wiring connections must be made employing suitable...

Страница 12: ...require different conduit knockouts to be used Any conduit knockouts may be used For power limited applications use of conduit is optional All field wiring connections must be made employing suitable...

Страница 13: ...E FACP Hook Up Diagrams Fig 8 Polarity reversal input from FACP signaling circuit output polarity is referenced in alarm condition N O TRIGGER INPUT TRG NO C NC FACP INTERFACE Fig 9 Normally Open Non...

Страница 14: ...rs Fused JUMPER N C DRY TRIGGER INPUT TRG NO C NC FACP INTERFACE Fig 11 Normally Closed Non Latching FACP trigger input N C TRIGGER INPUT N C RESET SWITCH JUMPER TRG Fig 12 Normally Closed Latching FA...

Страница 15: ...Maximal3V Maximal5V Maximal7V Access Power Controllers Fused 15 Notes...

Страница 16: ...50 8mm 2 50 8mm 6 25 158 75mm 6 25 158 75mm 4 101 6mm 4 101 6mm 2 50 8mm 4 101 6mm 8 9 226 06mm 8 4 213 36mm 7 177 8mm 7 177 8mm 7 177 8mm 8 4 213 36mm 8 5 215 9mm 8 5 215 9mm 7 5 190 5mm 10 254mm 1 5...

Отзывы: