Maximal11FV / Maximal33FV / Maximal55FV / Maximal77FV / Maximal75FV Access Power Controllers (Fused)

eFlow Power Supply/Chargers can be

Controlled and Monitored while Reporting

Power/Diagnostics from Anywhere

over the Network...

LINQ2 Mounts Inside any MaximalF Enclosure

LINQ2 - Network Communication Module

LINQ2 provides remote IP access to real-time data from eFlow power 
supply/chargers to help keep systems up and running at optimal 
levels. It facilitates fast and easy installation and set-up, minimizes 
system downtime, and eliminates unnecessary service calls, which 
helps reduce Total Cost of Ownership (TCO) - as well as creating a 
new source of Recurring Monthly Revenue (RMR). 

LINQ2 

Features:

-  UL Listed in the U.S. and Canada.
-  Local or remote control of up to (2) two Altronix eFlow power output(s) via LAN and/or WAN.
-  Monitor real time diagnostics: DC output voltage, output current, AC & battery status/service, 
  input trigger state change, output state change and unit temperature.
-  Access control and user managment: Restrict read/write, Restrict users to specific resources
-  Two (2) integral network controlled Form “C” Relays.
-  Three (3) programmable input triggers: Control relays and power supplies via external hardware sources.
-  Email and Windows Dashboard notifications
-  Event log tracks history.
-  Secure Socket Layer (SSL).
-  Programmable via USB or web browser - includes operating software and 6 ft. USB cable.

LINQ2 Module

Network

Connection:

Installation,

Programming

and Monitoring

L

G

N

NC

C

NO

NC

C

NO

BA

T F

AIL

AC F

AIL

AC

AC1

DC

TRIGGER EO

L

SUPER

VISE

D

disable

enable

2 hr

.

1 min

.

AC DELAY   

SHUTDOWN

O N

eFlow

Power

Supply/Charger

Содержание Maximal

Страница 1: ...utputs Maximal55FV Power Supply 1 12VDC 9 3A Power Supply 2 12VDC 9 3A Sixteen 16 fuse protected outputs Maximal77FV Power Supply 1 24VDC 9 6A Power Supply 2 24VDC 9 6A Sixteen 16 fuse protected outpu...

Страница 2: ...enance pg 6 Power Supply Board LED Diagnostics pg 7 Access Power Controller LED Diagnostics pg 7 Power Supply Board Terminal Identification pg 7 Access Power Controller Terminal Identification pg 8 Po...

Страница 3: ...Power Supply 1 Power Supply 2 A Fuse Protected Outputs 220VAC 50 60 Hz Input current Current per ACM8 output A Power Supply Board Input Fuse Rating Power Supply Board Battery Fuse Rating ACM8 Board In...

Страница 4: ...ed 1A 28VDC eFlow Power Supply Charger provides common power for ACM8 board factory wiring and all connected access control devices field wiring ACM8 board main fuses are rated 10A Output fuses are ra...

Страница 5: ...consists of one 1 power supply board that is factory set at 12VDC and one 1 power supply board that is factory set at 24VDC 4 Measure the output voltage of the unit before connecting any devices to e...

Страница 6: ...edge of the enclosure approximately 2 from the right side Fig 3b pg 10 Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device To activate alarm s...

Страница 7: ...erminals L to hot N to neutral Do not use terminal marked G DC Factory connected to ACM8 board Trigger EOL Supervised Fire Alarm Interface trigger input from a short or FACP Trigger inputs can be norm...

Страница 8: ...2VDC 5 3A P S 2 10 0 13 2VDC 5 3A or P S 1 20 28 26 4VDC 5 6A P S 2 20 28 26 4VDC 5 6A or P S 1 10 0 13 2VDC 5 3A and P S 2 20 28 26 4VDC 5 6A Maximal55FV P S 1 10 03 13 2VDC 9 3A and P S 2 10 03 13 2...

Страница 9: ...UT 2 IN GND 1 IN GND 2 IN GND 3 IN GND 4 IN GND 5 IN GND 6 IN GND 7 MAIN IN GND 8 LED2 LED3 LED4 LED5 LED6 LED7 LED8 J2 TRG FACP NC C NO COM OUTPUT 3 NC C NO COM OUTPUT 4 NC C NO COM OUTPUT 5 NC C NO...

Страница 10: ...largest batteries that can fit in this enclosure A UL listed external battery enclosure must be used if using the 40AH or 65AH batteries Optional Rechargeable Stand by Battery Optional Rechargeable St...

Страница 11: ...onduit is optional All field wiring connections must be made employing suitable gauge CM or FPL jacketed wire or equivalent substitute Optional UL Listed battery enclosure must be mounted adjacent to...

Страница 12: ...AND J2 ISOLATED POWER INPUT 12 OR 24 VAC OR VDC LOCK POWER ISOLATED POWER INPUT 12 OR 24 VAC OR VDC ACM8 POWER CUT JUMPER FROM FACP OUTPUT CIRCUIT FACP OUTPUT EOL TRG FACP NO C NC FACP INTERFACE JUMP...

Страница 13: ...Maximal11FV Maximal33FV Maximal55FV Maximal77FV Maximal75FV Access Power Controllers Fused 13 Notes...

Страница 14: ...14 Maximal11FV Maximal33FV Maximal55FV Maximal77FV Maximal75FV Access Power Controllers Fused Notes...

Страница 15: ...8 4 213 4mm 8 9 226 1mm 8 4 213 4mm 19 482 6mm 4 101 6mm 1 25 4mm 7 5 190 5mm 5 127mm 26 660 4mm 1 5 38 1mm 1 0 25 4mm 6 25 158 8mm 8 5 215 9mm 7 5 190 5mm 10 254mm 26 660 4mm 1 25 31 8mm 7 177 8mm 7...

Страница 16: ...the U S and Canada Local or remote control of up to 2 two Altronix eFlow power output s via LAN and or WAN Monitor real time diagnostics DC output voltage output current AC battery status service inpu...

Отзывы: